GREEN BANK LB24250 Скачать руководство пользователя страница 4

LiFePO4 Battery System for Households

LiFePO4 Battery System for Households

2.

4

 Recommended Settings

Lithium battery pack is not same as lead-acid battery, so for the devices which you connect with the battery 
pack for charging or discharging, such as inverters, MPPT charger controllers or UPS, please implement 
settings as recommended in the below table before functioning.

Setting 

Max. Charging Voltage 

 

Floating charging Voltage

Max. Charging Current

Cut-off voltage

Notes: “N” means the number of battery packs connected in parallel.

2.3 Specifications

Model

Nominal Voltage

Voltage Range

MAX. Charge & Discharge Current

Recommend Charge & Discharge Current

MAX. Output Power

Recommend Output Power

DOD

Modules Connection

Communication

Ingress Protection

Cycle Life

Working Temperature Range

Net Weight(KG) 

Gross Weight(KG)

Product Dimension(MM)

Package Dimension(MM)

≥95%

1~6in parallel

CAN&RS485

IP21         

6000@25°C        , 80%DOD 

Discharge:-20°C to +65°C, 0°C to +55°C 

03

04

57.6V

57.6V

48V

80A*N 

28.8 V  

28.8 V 

24V 

60A*N 

80A*N 

LB24250

LB48250

LB48200

Usable Capacity

Total capacity

685x475x213MM

73KG
89KG

LB48250

51.2

48-57.6

≤80A      

6000W

4000W

120A@30S

780x570x375MM

12KWH

9.5KWH

LB24250

25.6 

24-28.8 

≤80A  

3000W 

2000W 

120A@30S

537x537x298MM

450x415x213MM

39KG
44KG

6KWH

5KWH 

LB48200

51.2

48-57.6

≤60A      

6000W

3000W

120A@30S

620x410x205MM

53.8KG
67.7KG

715x505x365MM

10KWH

7.2KWH

LB48200&LB48250

Содержание LB24250

Страница 1: ...USER GUIDE LiFePO4 Battery System for Households LiFePO4 Battery System for Households 358 010262 00...

Страница 2: ...d Settings 4 3 INSTALLATION 5 3 1 Unpacking and Inspection 5 3 2 Mounting the Unit 5 3 3 Connection for Parallel Mode 6 4 OPERATION 9 4 1 Switch On O 9 4 2 Description for LED 10 4 3 ON OFF or SOC Led...

Страница 3: ...before attempting unit relocation 5 CAUTION Only quali ed solar electricians can install this device with the inverter charger 6 For optimum operation of this battery please follow required specs whe...

Страница 4: ...MAX Charge Discharge Current Recommend Charge Discharge Current MAX Output Power Recommend Output Power DOD Modules Connection Communication Ingress Protection Cycle Life Working Temperature Range Net...

Страница 5: ...battery wake up when the grid back connect the battery with grid use power adapter and communication line 1 shown in the package list The LB series battery support to be connected in parallel for expa...

Страница 6: ...time After con rming the correct connection of the inverter controller and battery you can turn on any of the switches and use the battery group that they are now act as one bank Note One group of LB...

Страница 7: ...OFF ON CELL TEMPERATURE LOW ON ON OFF ON CURRENT SENSOR ABNOMAL Sw1 SW2 SW3 SW4 Remarks 0 0 0 0 means ID 0 communication address is0x00 0x10 1 0 0 0 means ID 1 communication address is0x01 0 1 0 0 mea...

Страница 8: ...tion Induce vomiting and seek medical attention If the battery pack is wet or submerged in water do not let people access it and contact your supplier for help Damaged Batteries Damaged batteries are...

Отзывы: