GREEN BANK LB24150 Скачать руководство пользователя страница 5

06

07

LiFePO4 Battery System for Households

LiFePO4 Battery System for Households

4. OPERATION

Once the batteries are connected well, simply press On/Off button to enable the output of the battery pack.

24V

 

Over view

48V

 

Over view

Note

:

 One group of LB24V can be stacked up to 4 layers, and up to 6 in parallel connection

One group of LB48V can be stacked up to 2 layers, and up to 6 in parallel connection.

1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before 
    enable output. The LED will show the SOC.
2.Switch off: press and hold On/Off button for 3 seconds, the battery will shut down directly.
   Description for Communication port

4.1 Switch On / Off

Picture                                               PIN             Description

1

2

3

4

5

6

7

8

Trigger-GND

Trigger-VCC

NC

COMM-GND

RS485-B

RS485-A

CANL

CANH

The SOC of the battery is shown by the LED

4.2 Description for LED

DIP SWITCH

1-4

5

Communication Address

Termination Resister

Note: The battery need to be fully charged for at least once in one month to ensure the accurate SOC 
calculation.

100%                            75%                            50%                         25%              Flashing SOC<10%

For pure off grid system ,the PV awake wire need to be connected with MPPT charge controller if the battery 
pack is charged by solar panels only . The connection diagram as below :

4.3 ON / OFF or SOC Led (Mode or SOC)

BATTERY

 

MODE

ON/OFF

SOC

REMARK

GREEN

 

LED

RED

 

LED

 

LED1

   

LED2

   

LED3

   

LED4

 

POWER

 

OFF

OFF

OFF

OFF

OFF

OFF

OFF

POWER

 

ON

OFF

ON

ON

ON

ON

ON

STANDBY

OFF

OFF

SOC

SOC<10%(DEFAULT ):

 

LED1

 

FLASH

NORMAL

ON

OFF

RUNNING/SOC

SOC<10%(DEFAULT ):

 

LED1

 

FLASH

DISCHARGE

ON

OFF

SOC

SOC<10%(DEFAULT ):

 

LED1

 

FLASH

CHARGE

FLASH

OFF

RUNNING

LOW

 

POWER

FLASH

OFF

OFF

FAULT

OFF

ON

ON

OFF

OFF

OFF

BATTERY

 

VOLTAGE

 

HIGH

OFF

ON

OFF

OFF

BATTERY

 

VOLTAGE

 

LOW

ON

ON

OFF

OFF

CELL

 

VOLTAGE

 

HIGH

OFF

OFF

ON

OFF

CELL

 

VOLTAGE

 

LOW

ON

OFF

ON

OFF

CHARGING

 

CURRENT

 

HIGH

OFF

ON

ON

OFF

DISCHARGING

 

CURRENT

 

HIGH

ON

ON

ON

OFF

BMS

 

TEMPERATURE

 

HIGH

OFF

OFF

OFF

ON

BMS

 

TEMPERATURE

 

LOW

ON

OFF

OFF

ON

CELL

 

TEMPERATURE

 

HIGH

OFF

ON

OFF

ON

CELL

 

TEMPERATURE

 

LOW

ON

ON

OFF

ON

CURRENT

 

SENSOR

 

ABNOMAL

24V

 

Over view

48V 

Over view

Отзывы: