Multi Variable Air Conditioners Duct Type Indoor Unit
22
23
7 Table of Error Codes for Indoor Unit
Error
Code
Content
Error
Code
Content
Error
Code
Content
L0 Indoor Unit Error
L9 Quantity Of Group Control
Indoor Units Setting Error
d8 Water Temperature Sensor
Error
L1 Indoor Fan Protection
LA Indoor Units Incompatibility Error d9 Jumper Cap Error
L2 E-heater Protection
LH Low Air Quality Warning
dA Indoor Unit
Network Address Error
L3 Water Full Protection
LC Outdoor-Indoor Incompatibility
Error
dH Wired Controller Circuit Board
Error
L4 Power Supply
Overcurrent Protection
d1 Indoor Unit Circuit Board Error
dC Capacity DIP Switch Setting
Error
L5 Anti-freezing Protection
d3 Ambient Temperature Sensor
Error
dE Indoor Unit CO
2
Sensor Error
L7 No Master Indoor Unit
Error
d4 Inlet Pipe Temperature Sensor
Error
C0 Communication Error
L8
Power Insufficiency
Protection
d6 Outlet Pipe Temperature Sensor
Error
AJ Filter Cleaning Reminding
db Special Code:
Project Debugging Code
dL Outlet Air Temperature Sensor
Error
8 Troubleshooting
If your air conditioner is not working well, please check the following table first before asking for
service:
Phenomenon
Troubleshooting
The unit can’t start
①
Power supply is not connected
②
Circuit breaker tripping caused by leakage of electricity
③
Input voltage is too low
④
Operation button is off
⑤
Error of control loop
The unit stops after running for
a while.
①
There is obstacle in front of condenser
②
Error of control loop
③
Perform cooling when outdoor ambient temperature is higher than 43
℃
Poor cooling effect
①
The filter is dirty or blocked
②
Too heavy heat load of room(e.g. too many people)
③
Door or windows is open
④
Air inlet and outlet of IDU are blocked
⑤
Set temperature is too high or refrigerant leaks
⑥
The performance of room temperature sensor gets worse
Poor heating effect
①
The filter is dirty or blocked
②
Door or window is open
③
Set temperature is too low
④
Refrigerant leaks
⑤
Outdoor ambient temperature is lower than -5
℃
⑥
Error of control circuit
Indoor fan doesn’t start
up during heating
①
Position of tube temperature sensor is improper
②
Tube temperature sensor is not inserted well
③
Wiring of tube temperature sensor breaks off
④
Electrical leakage of capacitor