Air-to-water Heat Pump Split Versati
10
SPLIT
TYPE
3. Nomenclature
G
RS
-
C
Q
10
Pd
/
Nh
H
-
E
(O)
1
2
3
4
5
6
7
8
9
10
NO. Description
Options
1
GREE
G-GREE
2
Air to water heat pump
RS
3
Heating Mode
*` `
4
Function
{*] {
5
Nominal Heating Capacity
+}* +}* +}* +}*
6
Compressor Style
_ `*] ]^]
7
Refrigerant
Nh=R32
8
Design Serial Number
B,C,D,E......
9
Power Supply
E=230V,~,50Hz
10
Indoor and Outdoor Unit Code
*] ]
Model Line-Up
Model Name
Capacity
Power supply
Heating
1
,kW
Cooling
2
,kW
GRS-CQ4.0Pd/NhH-E
4
3.8
230VAC 50Hz
GRS-CQ6.0Pd/NhH-E
6
5.8
GRS-CQ8.0Pd/NhH-E
8
7
GRS-CQ10Pd/NhH-E
9.5
8.5
Notes
(a)
1
Capacities and power inputs are based on the following conditions:
}?`^?`#]`[^`}[*
(b)
2
Capacities and power inputs are based on the following conditions:
Indoor Water Temperature 23°C/18°C, Outdoor Air Temperature 35°C DB/24°C WB.
Operation Range
Mode
Heat Source Side Temperature (°C)
User Side Temperature (°C)
Heating
-25~35
20~60
Cooling
10~48
7~25
Water Heating
-25~45
40~80