SYSTEM CONFIGURATION

VENTILATION CONTROL

The unique ventilation system is activated by a two 
position control. Fresh outside air is redirected by 
the vent door to the indoor room. A polymer air filter 
prevents dirt and debris from entering the room from 
outdoors. The ventilation control lever is located at 
left side of unit, behind the front panel.

NOTE:

The vent door is screwed shut for shipping 

purposes. Remove shipping screw before using vent 
control lever. See Installation Instructions.

When vent is set at CLOSE, only the air inside the room 
is circulated and filtered.

When vent is set at OPEN, some outdoor air will be drawn 
into room. This will reduce heating or cooling efficiency.

ADJUSTING AIR DIRECTION

The bi-directional discharge grille is constructed of durable polycarbonate and is reversible. Air flows 
upward at a 40 degree angle to the floor but can easily be adjusted to an 80 degree angle to the floor.

To adjust air direction:

1.  Remove front panel.
2.  Remove louver screws that 

hold louver insert in place 
(from back side of front panel). 

3.  Turn louver insert and rotate 180°.
4.  Replace louver insert.
5.  Replace screws and front panel.

WARNING

CAUTION
WARNING

CAUTION

UNIT DAMAGE HAZARD 

– Failure to follow this

caution may result in equipment damage or improper
operation. Failure to remove shipping tape and 
screw will prevent fresh air vent door from opening
and may result in damage to vent door cable.

SHIPPING
TAPE

REMOVE SHIPPING
SCREW IF PRESENT

SHIPPING
TAPE

REMOVE SHIPPING
SCREW IF PRESENT

Vent Control (Pull 
lever through label 
to operate.) 

Louver screws 

Louver screws 

Air discharge upward

Air discharge outward (Default)

Adjusting Louvers

Vent Control (Pull 
lever through label 
to operate.) 

Louver screws 

Louver screws 

Air discharge upward

Air discharge outward (Default)

Adjusting Louvers

Fig. 14 – Ventilation Control

Vent Control (Pull 
lever through label 
to operate.) 

Louver screws 

Louver screws 

Air discharge upward

Air discharge outward (Default)

Adjusting Louvers

Fig. 15 – Backside of Front Panel

Fig. 16 – Adjusting Louvers

14

Vent Control (Pull 
lever through label 
to operate.) 

Louver screws 

Louver screws 

Air discharge upward

Air discharge outward (Default)

Adjusting Louvers

Fig. 13 – Shipping Screw Removal

Vent Control (Pull 
lever through label 
to operate.) 

Louver screws 

Louver screws 

Air discharge upward

Air discharge outward (Default)

Adjusting Louvers

Содержание TAC2-07HC265VA-A

Страница 1: ...PACKAGEDTERMINAL AIR CONDITIONER HEAT PUMP INSTALLATION OWNER S MANUAL PTAC DIRECT SALES INC 185 S Kimball Ave Suite 130 Southlake TX 76092 TEL 877 454 7822 T...

Страница 2: ...e has gone into your unit Please read this owner s manual carefully before operation and retain it for future reference ETACII PackagedTerminal Air Conditioner Heating Unit Table of Contents Safety Co...

Страница 3: ...r before making any repairs NOTE We strongly recommend that any servicing be performed by a qualified individual 2 Please read the following before installation or use Recognize safety information Thi...

Страница 4: ...del and serial number of unit on the space provided on the front page The model and serial number can be located on the serial number plate attached to unit UNIT INFORMATION NOMENCLATURE n o i t c e t...

Страница 5: ...So when power is restored the unit will start back up in the mode and configuration it was in when power was lost Premium Sound Your Premium ETAC II is also the quietest Gree PTAC Not only does it hav...

Страница 6: ...ment Sometimes known as Front Desk Control an input is provided so that the unit can be manually disabled from a different location If the unit detects 24vac on this input it will automatically turn i...

Страница 7: ...f of the coil 6 CONDENSATE REMOVAL SYSTEM ETAC II has a new condensate water disposal system The outdoor fan prop has a built in slinger ring which draws condensate water and sprays it on the warm out...

Страница 8: ...be ordered Be sure that your outlet matches the appropriate blade configuration of the plug and that it is within reach of the service cord All wiring including installation of the receptacle must be...

Страница 9: ...plate PROPER WALL RECEPTACLE OUTLET The unit plug configuration must match the electrical wall outlet and be within reach of the service cord The standard cord connected 265v units require an accessor...

Страница 10: ...sing non Gree grills WARNING CAUTION WARNING CAUTION 9 PROPER INSTALLATION IS THE RESPONSIBILITY OF THE INSTALLER Product failure due to improper installation is not covered under the limited ProductW...

Страница 11: ...al Electric Metal Sleeve RAB71 Plastic Sleeve RAB77 Amana Metal Sleeve WS900B Gree Metal Sleeve PTAC SLEEVE SE INS Plastic Sleeve SLEEVE INSUL 1PK Trane Metal Sleeve SLV149 Friedrich T Series Metal 11...

Страница 12: ...WARNING CAUTION WARNING WARNING Fig 4 GE Plastic Sleeve Remove bottom seal from plastic sleeve Fig 5 Accessory Baffle Kit Part BAFFLE KIT 1PK WINDOW WALL INSTALLATIONS This application has become mor...

Страница 13: ...lled using the appropriate power cord kit See Power Connection Chart below Unit Connec Junction Box Cover Junction Box Accessory Power Supply Cord Accessory Power Cord Unit Model ETAC2 07HC265VA A ETA...

Страница 14: ...the screws Fig 11 5 Re install junction box and cover Secure power cord a Re install junction box b Use wire clamp to secure power cord to basepan with screw provided c Replace junction box cover Wire...

Страница 15: ...ove front panel 2 Remove louver screws that hold louver insert in place from back side of front panel 3 Turn louver insert and rotate 180 4 Replace louver insert 5 Replace screws and front panel WARNI...

Страница 16: ...Dip Switch 3 down factory default Cooling Fan Control Switch 4 Set indoor fan to cycle mode with Dip Switch 4 up or continuous mode with Dip Switch 4 down factory default Electronic Temperature Limiti...

Страница 17: ...tinuous Run for Heating Fan Cycle for Cooling UP UP 68 75 F 20 24 C Freeze Guard Disable UP DOWN 63 80 F 18 28 C DOWN DOWN 61 86 F 16 30 C full range DOWN UP 65 78 F 19 26 C Down Heat Pump Control Pan...

Страница 18: ...FOR COOLING MODE Sometimes known as an anticipator the air temperature sensor bias is used to adjust the room air temperature reading when in cooling mode Not normally required Default biasing value...

Страница 19: ...thermostat wire 5 Route thermostat wire beneath ETAC II unit and up under the front panel on the power cord side see Fig 19 Never route thermostat wire through the wall sleeve 6 Locate thermostat conn...

Страница 20: ...ttach thermostat terminal block on unit 9 Locate configuration dip switches above thermostat terminal connections Set switch 2 UP forWall Thermostat Mode see Fig 17 10 Install thermostat escutcheon la...

Страница 21: ...led EM signal or front desk control The input signal must be 24VAC If unit receives a 24VAC signal it will turn off otherwise the unit runs normally This function will be disabled under Freeze Guard p...

Страница 22: ...n only operation 4 FAN SPEED Set fan operation for HI LO andAUTO speed Auto Fan Mode Adjusts the indoor fan speed to balance comfort and quietness Fan speed will increase the farther away from the sel...

Страница 23: ...l WARNING CAUTION WARNING CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Airflow restriction may cause damage to the unit WARNING CAUTIO...

Страница 24: ...ys or sooner depending on application Clogged filters reduce cooling heating and airflow 2 Air filters Coils Grille Dirty filter Needs cleaning Clogged filter Greatly reduces cooling heating and airfl...

Страница 25: ...sor overload DISPLAY HAS STRANGE NUMBERS CHARACTERS ON IT UNIT MAKING NOISES SOLUTIONS Check that plug is plugged securely in wall receptacle Note Plug has a test reset button on it Make sure that the...

Страница 26: ...t to FAN operation until ice or frost melts Remove and clean filters Random Compressor restart Whenever the unit is plugged in or power has been restarted a random compressor restart will occur After...

Страница 27: ...n on methods of control and use of air conditioning unit after initial installation 4 Damage or repairs needed as consequence of faulty installation or application This is the responsibility of the in...

Отзывы: