background image

6

Dust-collecting 

fi

 lter bracket

 

SP-240A

 

SP-260A

Panel

Filter Dust-collecting 

fi

 lter bracket

Filter 

sponge

Negative 

plate

Active carbon 

fi

 lter

Water tank

Water tray

Electrostatic 

fi

 lter sponge

Panel

Filter

Negative 

plate

Electrostatic 

fi

 lter 

sponge

Water tank

Water tray

Active carbon 

fi

 lter

Содержание SP-240A

Страница 1: ...Operation manual SP 240A Air purifier ...

Страница 2: ...ttery 20 Troubleshooting 21 Specifi cation 24 CONTENTS Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device plea...

Страница 3: ... power plug If there is much dust on the plug it may cause fire hazard If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Stop operation immediately in case of abnormality and malfunction occurred Example of abnormality and malfunction After installing the panel and putting through the power the product ...

Страница 4: ...age During operation if there s pet near the product please prevent it urinating on the product or biting the power cord It may cause electric shock or fire hazard Clean the water tank water tray and filter periodically Replace water with fresh tap water every day Pour out the residual water Clean the main unit periodically water tray filter This product can t be used for saving documents and pape...

Страница 5: ... decompose harmful substances through the unique absorption and decomposition function especially for low concentration formaldehyde HEPA high efficiency dedusting technology It can filter 0 3micron floating particles for refreshing indoor air Active carton absorptive technology This kind of active carton can eliminate ammonia acetic acid and other harmful gas in the air Plasma function Release cl...

Страница 6: ... SP 260A electrostatic humidified air purifier This kind of air purifier can eliminate smoke high efficiently for reducing the secondary pollution and protecting you and your family s health which is suitable for the places with plenty of smoke dust and pollen such as smoking area mahjong hall This air purifier has silver antiseptic filter LTC catalyst filter electromagnetic dedusting technology a...

Страница 7: ...ront panel Air inlet Air outlet Name plate Power cord Power plug SP 220A Panel Filter Dust collecting filter bracket Filter sponge Strainer sub assy Active carbon filter Water tank Water tray Front side Rear side Parts Name Handle ...

Страница 8: ...60A Panel Filter Dust collecting filter bracket Filter sponge Negative plate Active carbon filter Water tank Water tray Electrostatic filter sponge Panel Filter Negative plate Electrostatic filter sponge Water tank Water tray Active carbon filter ...

Страница 9: ...er magnetic places The product can t be operated normally Please put the product at the place where the fan can be reached to every corner Put the product at the stable place Otherwise it may increase the vibration of main unit Put the product at 2m away from the TV and other appliances to prevent interfering them Good position setting for air purifier Do not hold the handle of water tank to move ...

Страница 10: ... dust collector subassembly 3 Assemble filter into dust collector subassembly 4 Remove filtering sponge from package and assemble it in the dust collector 1 Take out the filter sponge and the install it into the dust collector 4 After assembling dust collector assemble front panel Please note that hangers on the unit shall be assembled firstly and the position is shown in the below picture 2 Draw ...

Страница 11: ...er tank in the unit If hearing click sound it means water tray has been inserted correctly Water tank Water tray When changing water pour out water remaining in water tray otherwise fouling or odor will be produced Notice Sensitivity of odor sensor is determined within 2 minutes after plugging in Therefore insert attaching plug when there is no odor Attaching plug Socket Notice Don t use the below...

Страница 12: ...tons in the unit and remote control will be locked to prevent child wrongly operating the unit 1 After pressing child lock button in remote control for 2 seconds the LED lamp of child lock will be on and child lock function is activated If any other button is pressed LED lamp of child lock will blinks and buzzer will sound 2 Press button of child lock for 2 seconds to release child lock Cleaning a...

Страница 13: ...P AUTO buttons simultaneously for over 1 seconds and then release them The unit enters adjustment mode for sensitivity degree of dust sensor In that case d1 d2 or d3 will be displayed In initial setting d1 will be displayed Number 1 2 3 means sensitivity degree Number 1 means lowest sensitivity degree number 2 means medium sensitivity degree and number 3 means highest sensitivity degree Press butt...

Страница 14: ...on and LED lamp for timer will be on Press button or to set time for turning on the unit When pressing timer button again LED lamp for timer will be off and timer will be canceled Press button of electrostatic dust removal to activate dust removal function and LED lamp for dust removal will be on This button is not available for model SP 220A In humidify mode it is used for setting humidity in tim...

Страница 15: ... range is 0 24 hours Press this button again to cancel the setting When the unit is operating timer is set for turning off the unit If the unit is turned off timer is set for turning on the unit When the unit is operating and this button is pressed the unit will automatically adjust negative ion electrostatic dust removal device and humidifying function based on sensed air quality and ambient rela...

Страница 16: ...tive carbon filter and use cleaner to remove dust When there is odor spray water on the surface and then dry it in air for about 1 day it can t be washed with water otherwise filter for removing odor will be deformed Refer to page 19 for replacement method Requirement Wipe the detergent after cleaning Don t use water which exceeds 50 Don t dry it in the place where there is direct sunlight Don t u...

Страница 17: ... is dirty Wash it with water Clean inside of water tank Fill water in water tank and shake water tank fiercely for 5 10 seconds Then pour out water If the inside is very dirty add a little of neutral detergent in water and shake water tank fiercely for 5 10 seconds Then pour it out and clean it with clear water subsequently Clean appearance of water tank Wipe it with dry cloth after cleaning it wi...

Страница 18: ... with water or Citric acid warm water then wash with water Requirement Do not remove the floater and degerming agent box The unit cannot operate normally without the floater and the water will be with odour soon without the degerming agent box For different water quality and environment the water in water tray will be color changed because of the scale Maintain the water tray as above stated Pleas...

Страница 19: ...pper arrow direction mark with remove the frame upper and the filter screen Press to wash the frame with clear warm water if the frame cannot be disassembled Match the bulge of lower frame and filter screen hole Incorrect assembly might cause water leakage 2 Assemble the new filter screen onto the frame lower Both sides of the filter screen are the same 3 Upper frame and shaft should be assembled ...

Страница 20: ...eave the fibre of cloth on the component Incorrect reaction might be caused 2 collect the surface dust with dust collecter 3 Dip in the water for 1hours 4 Wipe the dirt with cloth or soft brush Please wear cleaning gloves 5 Wash with water 6 Place it at ventilated and shady spot and dry out Open the panel take out the dedusting parts and remove the negative plate which need cleaning Hold the handl...

Страница 21: ...ith signature pen Y M Assemble the filter into dust collector rack be noted that the clamp should be proper assembled and the white side should be kept outward Assemble the whole dust collector into the unit see preparation before use Service life for replacement when the unit is operated for accumulative 2000 hours Service life for replacement 3 months Take out the filter sub assy remove the filt...

Страница 22: ...ith the doctor When the battery is not used any longer please put it into battery recycling place at the nearest electrical shop watch or camera stores The criteria for replacing battery is 1 year However if it is not found insensitive in receiving signals please replace the battery Please replace the battery as soon as possible when it is close to the battery lifespan In order to avoid the failur...

Страница 23: ...ged If the unit is inclined or tripped over There ll be click when the unit is start up or stopped There ll be bubble when the water in the tank flow into the tray It is the drive sound when the filter rotate during operation It is the sound when the water drop on the filter If the filter in dust collector is well assembled If the dust filter is taken off from the dust collector bag If the air ven...

Страница 24: ... the water tank If the fan motor is with malfunction Please contact with SINCLAIR store If the air inlet of the sensor is accumulated with dust clean the dust at air suction port with dust collector Operate the unit a while after dust collecting Does the floater cannot move because of the scale Clear the scale with brush Is the water tray well assembled Well assemble the water tray till a click is...

Страница 25: ... leakage Is the unit inclined Inclined unit might cause water splashing Stop operation when moving the unit pour out the water in water tank and water tray Is the cover of tank loosened Properly cover the tank Is the unit placed closely to the TV or TV antenna Is the power cord or antenna placed closely to the unit Please keep the unit far away from the TV radio and antenna The humidity shows on t...

Страница 26: ... 400 Net weight kg 11 11 11 Dimension mm 385X278X608 Applicable room area 14 18 18 The net weight is measured when the water tank is empty the flume is without water and the wet membrane is dry Humidifying volume is measured when the unit is under an ambient temperature of 20 2 relative humidity of 30 5 and high fan speed The standby power consumption is around 0 5W ...

Отзывы: