PROBLEM

System does not restart. 

Indoor unit emits unpleasant
odor when started.

You hear a “water flowing”
sound. 

A thin fog or vapor coming 
out of the indoor unit when 
system is running.

You hear a slight cracking 
sound when the system
stops or starts.

The system will not run. 

Cooling not running
efficiently. 

CAUSE/SOLUTION

Cause: 

The system has a built-in three-minute delay to prevent short and/or rapid cycling 
of the compressor.

Solution: 

Wait three minutes for the protection delay to expire.

Cause: 

Typically unpleasant odors are the result of mold or mildew forming on the coil 
surfaces or air filter.

Solution: 

Wash indoor air filter in warm water with mild cleaner. If odors persist, contact 
a qualified service professional to clean the coil surfaces.

Cause: 

It is normal for the system to make “water flowing” or “gurgling” sounds from 
refrigerant pressures equalizing when the compressor starts and stops.

Solution: 

The noises should discontinue as the refrigerant system equalizes after two or 
three minutes.

Cause: 

It is normal for the system to emit a slight fog or water vapor when cooling 
extremely humid warm air.

Solution: 

The fog or water vapor will disappear as the system cools and 
dehumidifies the room space.

Cause: 

It is normal for the system to make “slight cracking” sounds from parts expanding
and contracting during system starts and stops.

Solution: 

The noises should discontinue as temperature equalizes after two or three minutes.

Cause: 

There are a number of situations that will prevent the system from running.

Solution: 

Check for the following:
• Circuit breaker is “tripped” or “turned off.” 
• Power button of remote is not turned on. 
• Batteries in the remote controller are low. 
• Remote controller is in sleep mode or timer mode.
• Otherwise, you should contact a qualified service professional for assistance.

Cause: 

With routine maintenance, your system is designed for years of peak efficiency.

Solution: 

Check the following:
• Remove obstructions blocking airflow into the room.
• Clean dirty or blocked indoor air filter that is restricting airflow into the system.
• Seal outdoor air leaks in the room space from door or windows.
• Relocate (if possible) other heating sources in the room space.

19

20

TROUBLESHOOTING

Do not attempt any repairs on the unit yourself. Incorrect repair can cause shock or fire. 

Always call a qualified service professional. Using these troubleshooting suggestions can 

save time when you contact the qualified service professional.

WARNING

CAUTION
WARNING

CAUTION

Stop operation and call for service in the following circumstances:

• You hear a harsh or unusual sound during operation

• Unusually foul odor is emitted during operation

• Circuit breaker trips frequently, or unit stops 

abnormally often

TROUBLESHOOTING

TROUBLESHOOTING

PROBLEM

Wireless remote controller

lost or does not work.

Water leaking from 

indoor unit into the room.

The unit will not deliver air. 

Moisture or condensation

on the discharge

air louvers or outlet vents.

CAUSE/SOLUTION

Cause: 

There are a number of possible reasons.

Solution: 

Check the following:

• The batteries might be low. Change the batteries.

• The remote controller must be within 25 ft. (7.6 m) with no obstructions of the 

indoor unit. If remote controller is lost or damaged and needs to be replaced, 

contact your qualified service professional for assistance. In the meantime, 

use the manual override mode to operate the system.

Cause: 

While it is normal for the system to generate condensate water in cooling mode,

it is designed to drain this water to the outdoors via a condensate drain tube. 

If water is leaking into the room, it may indicate one of the following.

Solution: 

• The indoor unit is not level right to left. Level indoor unit.

• The condensate drain tube is restricted or plugged. All restrictions must be 

removed to allow continuous gravity force drainage.

• If problem persists, contact a qualified service professional for assistance.

Cause: 

There are a number of system functions that will prevent the indoor fan from running.

Solution: 

In dry mode, the indoor fan may stop for up to three minutes during the 

compressor off delay. Otherwise, you should contact a qualified service 

professional for assistance.

Cause: 

It is normal for the system to develop condensation or moisture on the 

discharge air louvers when cooling warm humid air for a long period of time.

Solution: 

The condensation or moisture will disappear as the system cools and 

dehumidifies the room space.

•  Water is leaking in the room

•  Liquid is spilled into unit

•  You notice a burning smell or 

see smoke

Содержание RIO09AC115V1A

Страница 1: ...HIGH WALL DUCTLESS AIR CONDITIONING SYSTEM Models as from on and ILITY LOW HIS arts rication mpany of OWNER S MANUAL RIO09AC115V1A RIO12AC115V1A RIO09AC230V1A RIO12AC230V1A RIO18AC230V1A RIO24AC230V1A ...

Страница 2: ... Rec sym inju wor DAN or d WA CAU inju NO relia Thank you for choosing a rioHigh Wall Ductless Air Conditioning System You can feel confident in your selection because the same pride in craftsmanship and engineering knowledge that goes into millions of other Gree installed products worldwide has gone into your unit Please read this owner s manual carefully before operation and retain it for future...

Страница 3: ... CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation t NOTE Your actual air conditioning system and related devices may differ from the images shown in this manual This appliance is not intended for use by children without respo...

Страница 4: ...hazard Keep combustible materials away from the unit Do not put hands or any objects into the air inlets or outlets This may cause personal injury or damage the unit When cleaning be careful not to splash water on the unit Doing this may cause electric shock or damage to unit Front Panel Display The front panel on the rio indoor unit contains system status lights and an easy to read LED display NO...

Страница 5: ... LED 3 MP PART NAMES Indoor unit Part Name 1 Remote Controller 2 Front Panel 3 Air Filter 4 Horizontal Louver 5 Wall Hole Sleeve 6 Insulation 7 Refrigerant Pipes 8 Drain Hose Outdoor unit 2 3 6 5 8 7 4 ed 1 ...

Страница 6: ...ons described below If your unit does not come equipped with a certain function the button will be inactive ON OFF Button Pressing this button will turn the unit on and off Using the ON OFF function will cancel TIMER and SLEEP functions but preset times will not be affected MODE Button Pressing this button will present the COOL DRY and FAN mode options which can then be selected When the indoor un...

Страница 7: ...5 6 OPERATION OF WIRELESS REMOTE CONTROLLER ON OFF Button MODE Button FAN Button SignalTransmitter ons e ...

Страница 8: ...on push the TURBO button This will force the unit to run at ultra high speed When TURBO mode is running the TURBO icon is displayed on the remote controller X FAN Button Press the X FAN button to allow the indoor fan to run for 10 minutes after the unit is turned off cooling or dry modes only to ensure that additional moisture is removed from coil X FAN icon will be displayed on remote controller ...

Страница 9: ...7 8 OPERATION OF WIRELESS REMOTE CONTROLLER Button Button TURBO Button X FAN Button LIGHT Button ...

Страница 10: ... to room setpoint after 5 seconds When the indoor unit first powers on it will display the room setpoint setting Look for the thermometer icon to appear inside or outside the house icon on the remote controller display indicating whether the front panel is displaying room setpoint indoor or outdoor temperatures SLEEP Button Press the SLEEP button to activate SLEEP function and select one of three ...

Страница 11: ...ble 9 OPERATION OF WIRELESS REMOTE CONTROLLER 10 SLEEP Button TEMP Button VERTICAL SWING LOUVER Button TIMER ON OFF Button ...

Страница 12: ... entered The unit will emit an audible beep when the signals are received correctly ON OFF BUTTON When the system is in OFF mode the remote controller will display the time and last room setpoint When you press the ON OFF button the unit will start in the last operating mode and room setpoint NOTE If the ON OFF button is pressed too soon after a stop the compressor will not start for 3 minutes due...

Страница 13: ...ure FAN ONLY To circulate air without cooling Use Fan Speed button to select speed from low to high DRY Select DRY MODE to increase moisture removal during warm humid conditions 1 RoomTemperature Setpoint 4 F the system will be operating in cooling mode with low fan speed 2 Setpoint 4 F RoomTemperature Setpoint 4 F the system will cycle 6 minutes ON and 4 minutes OFF in cooling mode The indoor fan...

Страница 14: ...d amount of time after the unit is turned off cooling or dry modes to ensure that additional moisture is removed from coil Push the X FAN button to enable this feature The X FAN icon will be displayed on remote controller To deactivate this feature push the X FAN button again TIMER MODE The Rio can be programmed to automatically turn ON or OFF after a selected time period Press TIMER button to act...

Страница 15: ...n temperature will not affect your comfort level due to the natural effects that sleeping has on the body but it will save on energy consumption and will lower your electric bill Press the SLEEP button to select Sleep Mode The SLEEP icon will appear In Cool or Dry modes The unit will run at current room setpoint for 1 hour After 1 hour the setpoint will increase by 2 F After 2 hours the setpoint w...

Страница 16: ...when operating When remote emits a signal icon will flicker a tone will be heard when unit receives that signal Remove old batteries Install new batteries CHANGING BATTERIES Manual Switch EMERGENCY OPERATION Use the Manual Override button to manual operate the unit if the remote controller is lost or damaged Lift up the front panel section on the indoor unit and locate the Manual Override button o...

Страница 17: ... failure When power is returned the neo system will automatically return to the last operating mode POLYMERIC AIR FILTER The polymeric mesh filters save energy by preventing the indoor coils from being plugged with dirt and lint This economical and sturdy filter may be washed vacuumed and reused Optional Function PHOTOCATALYTIC FILTER PhotocatalyticAir Filter is a second stage filter that oxidizes...

Страница 18: ...rasive cleaners on indoor or outdoor unit Use only slightly damp clean soft cloth or very mild cleansers CLEANING THE FRONT PANEL 1 To remove front panel for cleaning lift up and pull out 2 Wash the panel with water a soft cloth or soft brush Use only very mild cleaners Then dry completely NOTE Take down the display panel before cleaning Never use water above 113 F 45 C because it may cause discol...

Страница 19: ...cleaner Air dry filter in the shade Never use fire to clean stains or debris on filter 3 Reinsert the filter being careful to align properly then close unit CLEANING OPTIONAL PHOTOCATALYTIC FILTER Clean every 2 weeks for the best results 1 Remove photocatalytic filter from front face of primary air filter 2 Clean lint and dust from air filter using vacuum NOTE Do not get photocatalytic filter wet ...

Страница 20: ... water vapor will disappear as the system cools and dehumidifies the room space Cause It is normal for the system to make slight cracking sounds from parts expanding and contracting during system starts and stops Solution The noises should discontinue as temperature equalizes after two or three minutes Cause There are a number of situations that will prevent the system from running Solution Check ...

Страница 21: ...rate the system Cause While it is normal for the system to generate condensate water in cooling mode it is designed to drain this water to the outdoors via a condensate drain tube If water is leaking into the room it may indicate one of the following Solution The indoor unit is not level right to left Level indoor unit The condensate drain tube is restricted or plugged All restrictions must be rem...

Страница 22: ...e selected room temperature Your neo unit will operate in cooling down to 41 F 5 C Indoor Coil Freeze Protection Frost may form on the indoor coil during cooling operations when the outdoor temperature below 50 F 10 C Prolong operation may cause ice to form on the indoor coil and block airflow If the neo indoor unit microcomputer detects ice on the indoor coil it will stop the compressor to defros...

Страница 23: ...of a chair or the front of a sofa instead of the actual living space Use the Swing Louvers to help direct the air in the right direction for the room remove or rearrange obstacles blocking airflow 6 Try 75 degrees 75 F is a good point for an air conditioner to run at its optimal performance level Even a 5 degree change in temperature can make your unit use up to 40 more energy 7 Lighting Turning l...

Страница 24: ...TSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replacement parts or new units 2 Normal maintenance as outlined in the installation and servicing instructions or Owner s Manual including filter cleaning and or replacement and lubrication 3 Failure damage or repairs due to f...

Отзывы: