BU Module
23
9
Troubleshooting
-------------------------------------------------------------------------------------------------------------------------
Caution!
ƹ
In the event of abnormal conditions (like stinky smell), please shut off the power supply
immediately and then contact the appointed service center; otherwise, the abnormal running
would damage the air conditioner and also would cause electric shock or fire etc.
ƹ
Do not repair the air conditioner personally but instead of contact the professionally skilled
personnel at the appointed service center, as the incorrect repair would cause electric shock or
fire etc.
-------------------------------------------------------------------------------------------------------------------------
Table 12
Indicating LED flashing times
Errors
Yellow
LED
Green
LED
Red
LED
Indoor
unit error
code
Outdoor unit
error code
BU 1 is connected
Flash 1 time
BU 2 is connected
Flash 2 times
BU 3 is connected
Flash 3 times
Indoor unit A is connected
Flash 1 time
Indoor unit B is connected
Flash 2 times
Indoor unit C is connected
Flash 3 times
Indoor unit A gas tube
temperature sensor error
Flash 1
time
b7
b7 indoor unit
address
Indoor unit A liquid tube
temperature sensor error
Flash 2
times
b5
b5 indoor unit
address
Indoor unit B gas tube
temperature sensor error
Flash 3
times
b7
b7 indoor unit
address
Indoor unit B liquid tube
temperature sensor error
Flash 4
times
b5
b5+ indoor unit
address
Indoor unit C gas tube
temperature sensor error
Flash 5
times
b7
b7 indoor unit
address
Indoor unit C liquid tube
temperature sensor error
Flash 6
times
b5
b5 indoor unit
address
10 After-Sales Service
If there is any quality or other issue, please contact the after-sales service center.
Содержание RFX12A