background image

20

Checking for gas leakage

1)Check for leakage of gas after air purging
2)See the sections on air purges and gas leak checks in
the installation manual for the outdoor unit.

Attaching the connection pipe

Check for leakage here

Apply soapy water and ch-

eck carefully for leaking gas.

wipe soapy water off after

the check is complete.

Attach the pipe after checking for gas leakage, described above.

1)Cut the insulated portion of the on-site piping, matching it up with the connecting portion.
2)Secure the slit on the refrigerant piping side with the butt joint on the auxiliary piping using the tape, making sure there
are no gaps.
3)Wrap the slit and butt joint with the included insulation sheet, making sure there are no gaps.

Refrigerant

pipe

Refrigerant

pipe

Refrigerant

pipe

Slit

Slit

Tape

Auxiliary pipe

Insulation sheet

CAUTION

1)Insulate the joint of the pipes securely.
Incomplete insulation may lead to water leakage.
2)Push the pipe inside so it does not place undue force on the front grille.

Connecting the drain hose

Insert the supplied C drain hose into the socket
of the drain pan.
Fully insert the drain hose until it adheres to a
seat of the socket.

Drain pan

Seal

Drain pan

Seal
Drain hose

INSTALLATION INSTRUCTIONS

Installation of indoor unit

Содержание Multi21 CONS12HP230V1AF

Страница 1: ...ou have lost the Owner s Manual please contact your local distributor or visit www greecomfort com or send an email to info twclimate com for the electronic version Installation Owner s Manual Original Instructions Split Air Conditioner Models CONS09HP230V1AF GEH 09 AA D3DNA1C I CONS12HP230V1AF GEH 12 AA D3DNA1C I CONS18HP230V1AF GEH 18 AA D3DNA1C I ...

Страница 2: ...ven supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance External static pressures at the appliance was tested is 0 Pa Fuse link T250 V 3 15 A One of the benefits awaiting you with our room air conditioner is not only comfort of life but also good health This operation in...

Страница 3: ...d the unit 15 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Settings changed beep 14 Indoor Unit ON OFF switch Push this switch once to start operation Push once again to stop it 2 Air outlet 3 Display 4 Front panel 5 Louvers vertical blades The louvers are inside of the air outlet 6 Air inlet 7 Air filter 8 Flap horizonta...

Страница 4: ... 16 LIGHT button 8 7 button 4 14 T ON T OFF button Send signal Turbo mode 8 heating function Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Set fan speed Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Clock Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel Healthy mode Scavenging functio...

Страница 5: ...the suitable operation mode in accordance with the room temperature to make indoor room comfortable 3 This button is used for setting Fan Speed in the sequence that goes from AUTO to then back to Auto FAN 1 4 3 2 5 Press this button to turn on the unit Press this button again to turn off the unit Press this button to decrease set temperature Holding it down above 2 seconds rapidly decreases set te...

Страница 6: ...initial curve setting value of original factory 2 hours or 3 hours or 8 hours the place of setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink temperature display will resume to original setting temperature Sleep3 the sleep curve setting under SLEEP mode by DIY could be inquired The user could accord to sleep curve setting method to inquire the p...

Страница 7: ...on to turn on the display s light and press this button again to turn off the display s light If the light is turned on is displayed If the light is turned off disappears TURBO 14 X FAN 16 Pressing X FAN button in COOL or DRY mode the icon is displayed and the indoor fan will continue operation for a while minutes in order to dry the indoor unit even though you have turned off the unit After energ...

Страница 8: ...ert them after 30 seconds If it still can t operate properly Notes replace the batteries Sketch map for replacing batteries Replacement of Batteries At unit OFF press MODE and buttons simultaneously to switch between and About Back lighting Function 21 Combination of MODE and buttons 18 About switch between Fahrenheit and centigrade Press TEMP and CLOCK simultaneously in COOL mode to start energy ...

Страница 9: ...ront panel into the grooves of the unit 3 places Press the claws on the right and left of the air filter down slightly then pull upward 3 Take off the Titanium Apatite Photocatalytic Air Purifying Filter Hold the tabs of the frame and remove the claws in 4 places Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When removing or attaching the front pa...

Страница 10: ...ilters may result in troubles as dust will accumulate inside the indoor unit If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade Dispose of the old filter as flammable waste Dispose of the old filter as flammable waste It is recommended to clean the air filters every week Air filter Titanium Apatite Photocatalytic Air Puri...

Страница 11: ...oller Press MODE button and select FAN operation Press ON OFF button and start operation 3 4 Before a long idle period Check NOTE Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit Check that the drain comes smoothly out of the drain hose during COOL or DRY ope...

Страница 12: ...or ambient temperature decreased its cooling capacity will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Principle Air conditioner absorbs heat from ...

Страница 13: ...11 Operating guide OPERATION INSTRUCTIONS ...

Страница 14: ...12 OPERATION INSTRUCTIONS Precautions 5 ...

Страница 15: ...13 OPERATION INSTRUCTIONS CAUSES PROBLEM Checking before contact the service man 6 ...

Страница 16: ... unit installation drawings are met 2 both air intake and exhaust have clear paths met 3 the unit is not in the path of direct sunlight 4 the unit is away from the source of heat or steam 5 there is no source of machine oil vapour this may shorten indoor unit life 6 cool warm air is circulated throughout the room 7 the unit is away from electronic ignition type fluorwscent lamps inverter or rapid ...

Страница 17: ... length The suggested shortest pipe length is 2 5m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used See the installation manual for the outdoor unit for the maximum pipe length CAUTION 350 wall Refrigerant pipe 45 75 Floor 45 45 45 45 60 75 75 75 75 45 Left back piping...

Страница 18: ...to check the water flows smoothly 100 Drain hose 100 150 Vinyl chloride drain pipe 50mm or more Reducer Must be no trap Do not touch water 16 INSTALLATION INSTRUCTIONS Installation of indoor unit Boring a wall hole and installing wall embedded pipe For walls containing metal frame or metal board be sure to use a wall embedded pipe and wall cover in the feed through hole to prevent water leakage Be...

Страница 19: ...sings 2 tabs on each side 4 Remove the slit portions on the bottom frame and casings using nippers 5 Return by following the steps in reverse order 3 2 1 3 Side casings 2 Upper casing 3 Side casings Remove the pillar Remove 7 screws Casing Remove the pillar Casing Remove the pillar Bottom frame Secure using 6 screws for floor installations Do not forget to secure to the rear wall For wall installa...

Страница 20: ... chips do not enter the pipe 3 Fit the flare nut on the pipe 4 Flare the pipe 5 Check that the flaring is properly made WARNING 1 DO not use mineral oil on flared part 2 Prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which had been used for previous installations Only use parts which are delivered with the unit 4 Do never install ...

Страница 21: ...ius should be 30 to 40mm or larger Gas pipe Gas pipe insulstion Finising tape Inter unit wiring Liquid pipe Liquid pipe insulation Selection of copper and heat insulation materials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052W mK 0 035 to 0 045kca mh Refrigerant gas pipe s surface temperature reaches...

Страница 22: ...piping side with the butt joint on the auxiliary piping using the tape making sure there are no gaps 3 Wrap the slit and butt joint with the included insulation sheet making sure there are no gaps Refrigerant pipe Refrigerant pipe Refrigerant pipe Slit Slit Tape Auxiliary pipe Insulation sheet CAUTION 1 Insulate the joint of the pipes securely Incomplete insulation may lead to water leakage 2 Push...

Страница 23: ...they may cause overheating electrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may cause electric shock or fire 21 INSTALLATION INSTRUCTIONS Installation of indoor unit Outdoor unit Indoor unit Firmly fix the wires with the terminal screws Firmly fix the wires with the terminal s...

Страница 24: ...been connected to a secure earth connection Is the power cord specified Has the inlet and outlet been covered Has the length of connection pipes and the refrigerant charge been record The unit may drop shake or emit noise It may cause insufficient refrigerating capacity It may cause condensation and dripping It may cause condensation and dripping It may cause electric malfunction or damage the par...

Страница 25: ...of refrigerant oil for each additional 5m of connection pipe The calculation method of additional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant char...

Страница 26: ...l refrigerant charging amount in Sheet 2 is recommended value not compulsory Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m Ф6 Ф9 5 or Ф12 20 15 20 Ф6 or Ф9 5 Ф16 or Ф19 50 15 50 Ф12 Ф19 or Ф22 2 100 30 120 Ф16 Ф25 4 or Ф31 8 170 60 120 Ф19 250 250 250 Ф22 2 350 350 350 ...

Страница 27: ...PLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com 66162665 CAT NO GREE_MULTI_MINI CONSOLE_A_INSTALL OWNERS_061119 ...

Отзывы: