INSTALLATION OF CEILING CASSETTE
Step 1 - Selecting Location for Ceiling Cassette Unit
Select a location that allows for the following:
•
Ensure the installation complies with the installation minimum dimensions and meets the
minimum and maximum connecting piping length and maximum change in elevation.
•
Air inlet and outlet will be clear of obstructions, ensuring proper airflow throughout the room.
•
Condensate can be easily and safely drained.
•
All connections can be easily made to outdoor unit.
•
Indoor unit is out of reach of children.
•
A ceiling strong enough to withstand four (4) times the full weight and vibration of the unit.
•
Filter can be easily accessed for cleaning.
•
Leave enough free space to allow access for routine maintenance.
•
Install at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air
conditioner may interfere with radio or TV reception in areas where reception is weak. An
amplifier may be required for the affected device.
•
Do not install in a laundry room or by a swimming POOL.
•
The location meets all the minimum clearance dimensions and the requirements of the schematic
diagram.
Step 2 - Laying Out Location
•
Locate the factory supplied installation template included in carton.
•
Use the template to make an opening in the ceiling for the ceiling cassette main body.
•
Mark the position of the hanger bolts, refrigerant lines and condensate drain pipes,
interconnecting cable and wired remote controller wires ( if applicable).
.