INDOOR UNIT COMBINATIONS
Model No: MULTI36HP230V1A
36,000 BtuH (cont.)
Heating Capacity (BtuH)
9K+9K+12K
27,024
15,354~33,780
7,694
8,069
11,260
9K+9K+18K
35,622
15,354~37,533
8,598
8,598
18,425
9K+9K+24K (2)
35,622
15,354~37,533
7,574
7,574
20,472
9K+12K+12K
35,622
15,354~37,533
9,008
13,307
13,307
9K+12K+18K
35,622
15,354~37,533
7,370
12,078
16,173
9K+12K+24K (2)
35,622
15,354~37,533
6,551
9,622
19,449
9K+18K+18K
35,622
15,354~37,533
7,165
14,126
14,126
9K+18K+24K (2)
35,622
15,354~37,533
6,551
10,850
18,220
12K+12K+12K
35,622
15,354~37,533
11,874
11,874
11,874
12K+12K+18K
35,622
15,354~37,533
10,236
10,236
15,149
12K+12K+24K (2)
35,622
15,354~37,533
9,008
9,008
17,606
12K+18K+18K
35,622
15,354~37,533
11,055
14,740
14,740
18K+18K+18K
35,622
15,354~37,533
11,874
11,874
11,874
9K+9K+9K+9K
40,126
15,354~40,945
10,031
10,031
10,031
10,031
9K+9K+9K+12K
40,126
15,354~40,945
9,008
9,008
9,008
13,102
9K+9K+9K+18K
40,126
15,354~40,945
8,189
8,189
8,189
14,740
9K+9K+9K+24K (2)
40,126
15,354~40,945
7,370
7,370
7,370
18,016
9K+9K+12K+12K
40,126
15,354~40,945
8,189
8,189
11,874
11,874
9K+9K+12K+18K
40,126
15,354~40,945
7,574
7,574
10,645
14,740
9K+9K+18K+18K
40,126
15,354~40,945
6,551
6,551
13,512
13,512
9K+12K+12K+12K
40,126
15,354~40,945
9,417
10,236
10,236
10,236
9K+12K+12K+18K
40,126
15,354~40,945
7,370
9,008
9,008
14,740
12K+12K+12K+12K 40,126 15,354~40,945 10,031 10,031 10,031 10,031
INDOOR UNITS
COMBINATIONS
RATED
SYSTEM
CAPACITY
(BtuH)
CAPACITY
RATING
(MIN – MAX)
(BtuH)
INDOOR
UNIT A
(BtuH)
INDOOR
UNIT B
(BtuH)
INDOOR
UNIT C
(BtuH)
INDOOR
UNIT D
(BtuH)
Notes:
1) It is critical to size the outdoor unit for the entire building load and each indoor unit for its individual zone load.
2) 24K size is reserved for Ceiling Cassettes, Concealed Ducts, and Floor/Ceilings units only. Not Wall Mount units.
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions:
Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB
Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB
Outdoor: 47°F DB/43°F W
23