19
INDOOR UNIT COMBINATIONS
Model No: MULTI24HP230V1A
24,000 BtuH
Cooling Capacity (BtuH)
Heating Capacity (BtuH)
9K+9K
18,000
6,824~26,600
9,000 9,000
9K+12K
21,000
7,165~27,300
9,000 12,000
12K+12K
24,000
7,200~30,000
12,000 12,000
9K+18K
25,000
7,300~32,000
8,400 16,600
12K+18K
25,000
7,400~32,500
10,000 15,000
18K+18K
25,500
7,500~32,500
12,750
12,750
9K+9K+9K
26,000
7,500~34,000
8,667
8,667
8,667
9K+9K+12K
26,000
7,500~34,000
8,000
8,000
10,000
9K+12K+12K
26,000
7,500~34,000
6,000
10,000
10,000
9K+9K+18K
26,000
7,500~34,000
7,000
7,000
12,000
12K+12K+12K
26,000
7,500~34,000
8,667
8,667
8,667
9K+9K
19,000
71,00~33,000
9,500
9,500
9K+12K
22,500
7,100~33,500
9,500 13,000
12K+12K
26,000
7,200~34,000
13,000 13,000
9K+18K
27,000
7,300~34,000
9,000 18,000
12K+18K
28,000
7,400~34,000
11,200
16,800
18K+18K
28,500
7,400~34,400
14,250
14,250
9K+9K+9K
29,000
7,500~35,000
9,667
9,667
9,667
9K+9K+12K
29,000
7,600~35,000
9,000
9,000
11,000
9K+12K+12K
29,000
7,600~35,000
6,000
11,500
11,500
9K+9K+18K
29,000
7,600~35,000
6,000
6,000
17,000
12K+12K+12K
29,000
7,600~35,000
9,667
9,667
9,667
INDOOR UNITS
COMBINATIONS
INDOOR UNITS
COMBINATIONS
RATED SYSTEM
CAPACITY
(BtuH)
RATED SYSTEM
CAPACITY
(BtuH)
CAPACITY RATING
(MIN – MAX)
(BtuH)
CAPACITY RATING
(MIN – MAX)
(BtuH)
INDOOR
UNIT A
(BtuH)
INDOOR
UNIT A
(BtuH)
INDOOR
UNIT B
(BtuH)
INDOOR
UNIT B
(BtuH)
INDOOR
UNIT C
(BtuH)
INDOOR
UNIT C
(BtuH)
Note:
It is critical to size the outdoor unit for the entire building load and each indoor unit for its individual zone load.
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions
Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB
Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB
Outdoor: 47°F DB/43°F W