8.2.1 Outline and dimension of the outdoor unit
8.2 Installation Instruction
NAME OF PARTS
WARNING
● If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
● Be sure to cut off the power supply before cleaning the air conditioner; otherwise electricshock might happen.
● Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
● Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean
the air conditioner cabinet).
● Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
● The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
OUTDOOR UNIT
No. Description
1
Air outlet grille
2
Valve
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to
the appearance of the units that have been purchased
TECHNICAL DATA
MODE
MULTIU18HP230V1DO
MULTIU24HP230V1DO
MULTIU36HP230V1DO
MULTIU42HP230V1DO
Electrical data
Electricity supply
208/230V,60HZ
208/230V,60HZ
208/230V,60HZ
Fuse or air switch
35
40
60
A
Minimum power cord section
AWG10
AWG10
AWG8
Size and clearance
L
36 7/21
36 7/21
40
inch
P
14 61/64
14 61/64
17 21/64
inch
H
31 7/64
31 7/64
43 27/64
inch
OUTDOOR UNIT WORKING TEMPERATURE RANGE
OutdoorsideDB/WB(
O
c )
Maximum cooling
115°F(46°C)/-
Maximum heating
75.2°F(24°C)/-
1
1
2
2
P
L
H
18/24K
36/42K