OPERATING METHODS
-
4
-
The working range is 16
℃
-3
0
℃
.
When operating, the unit should be placed on the horizontal place, more
than 50cm away from the wall
or
other obstructions.
The working range of COOL
mode and DRY mode.
Location requirement
Power supply
Before the unit is power-on, please check the following:
The standard working range of the voltage is 220/2
4
0V 6%, 50Hz,
if the voltage is higher or lower, the air conditioner will be affected.
●
The lead wire is suitable for more than 20A start-up current, in order
to avoid the voltage decline when the unit starts suddenly.
●
The power plugs and the sockets can be supported by the current
that is more than 16A.
●
The thread section of the lead wires and any continued use lead wire
is no less than 2.5mm
2
.
●
If the power supply cord is damaged, should adopt the special
power supply cord to replace.
●
If the power supply is needed to replace or maintain, please
contact with the dealer and ask for the professional to do
the repairing work.
●
The air conditioner must be safety earthed. Earth wire must be
connected to the special device of the building. In order to provide
the good earthing for the air conditioner.
50
cm
5
0
c
m