97
Service Manual
Installation and Maintenance
to remove the cover.
Remove every wiring terminals, and remove the
electric box cover sub-assy.
Remove the screws fixing connection pipe
clamp, to remove the connection pipe clamp.
8.Remove evaporator sub-assy
electric box cover sub-assy
screw
electric box cover
screw
auxiliary piping
pipe clamp
screw
Steps
Procedure