background image

3

Technical Information

Service Manual

6SHFL¿FDWLRQV

6SHFL¿FDWLRQ6KHHW

Model

1.GWH18RC-K3DNA3C
2.GWH18RC-K3DNA2C
3.GWH18RC-K3DNA6C

1.GWH24RD-K3DNA3C
2.GWH24RD-K3DNA2C
3.GWH24RD-K3DNA6C

Product Code

1.CB302001100

2.CB301001300
3.CB305000300

1.CB302001400
2.CB301001400
3.CB305000400

Power
Supply

Rated Voltage

V

̚

220-240

220-240

Rated Frequency

Hz

50

50

Phases

1

1

Power Supply Mode

Indoor

Indoor

Cooling Capacity 

W

5275

6450

Heating Capacity 

W

5275

6450

Cooling Power Input 

W

1620

1940

Heating Power Input

W

1600

1910

Cooling Power Current

A

7.19

8.5

Heating Power Current

A

7.10

8.5

Rated Input

W

2500

3050

Rated Current

A

10.87

13.85

Air Flow Volume (SH/H/M/L/SL)  

m

3

/h

850/780/740/300/-

1000/800/700/600/-

Dehumidifying Volume

L/h

1.8

2.5

EER

W/W

3.26

3.32

COP W/W

3.30

3.38

SEER

W/W

/

/

HSPF

W/W

/

/

Application Area

m

2

23-34

27-42

Indoor  Unit 

Model of indoor unit

1.GWH18RC-K3DNA3C/I
2.GWH18RC-K3DNA2C/I
3.GWH18RC-K3DNA6C/I

1.GWH24RD-K3DNA3C/I
2.GWH24RD-K3DNA2C/I
3.GWH24RD-K3DNA6C/I

Fan Type

&URVVÀRZ

&URVVÀRZ

Diameter Length (DXL) 

mm

ĭ;

ĭ;

Fan Motor Cooling Speed (SH/H/M/L/SL) 

r/min

1350/1200/1000/800/-

1350/1150/950/850/-

Fan Motor Heating Speed (SH/H/M/L/SL) 

r/min

1420/1250/1100/950/-

1400/1200/1000/900/-

Output of Fan Motor

W

20

35

Fan Motor RLA

A

0.31

0.31

Fan Motor Capacitor 

ȝ)

1.5

2.5

Input  of  Heater

W

/

/

Evaporator Form 

Aluminum Fin-copper Tube

Aluminum Fin-copper Tube

Pipe Diameter

mm

ĭ

ĭ

5RZ¿Q*DS

mm

2-1.4

2-1.5

Coil Length (LXDXW)

mm

715X25.4X304.8

765X25.4X342.9

Swing Motor Model

MP28VB

MP35XX

Output of Swing Motor 

W

2.0

2.5

Fuse

A

3.15

3.15

Sound Pressure Level (SH/H/M/L/SL) 

dB (A) 

48/46/37/33/-

50/45/39/36/-

Sound Power Level (SH/H/M/L/SL) 

dB (A) 

58/56/47/43/-

60/55/49/46/-

Dimension (WXHXD) 

mm

945X298X208

1018X315X223

Dimension of Carton Box (LXWXH)

mm

1010X380X285

1083X395X313

Dimension of Package (LXWXH)

mm

1013X383X300

1086X398X328

Net Weight  

kg

13

15.5

Gross Weight

kg

16

19

Содержание GWH18RC-K3DNA2C

Страница 1: ...Service Manual GWH18RC K3DNA2C GWH18RC K3DNA3C GWH18RC K3DNA5C GWH18RC K3DNA6C GWH18RC K3DNA8C GWH18RC K3DNA9C white panel GWH18RC K3DNA9C silver grey panel GWH24RD K3DNA2C GWH24RD K3DNA3C GWH24RD K3D...

Страница 2: ...5 Electrical Part 15 5 1 Wiring Diagram 15 5 2 PCB Printed Diagram 19 6 Function and Control 22 6 1 Remote Controller Introduction 22 6 2 Brief Description of Modes and Functions 26 Part Installation...

Страница 3: ...arts List 61 10 1 Indoor Unit 61 10 2 Outdoor Unit 71 11 Removal Procedure 79 11 1 Removal Procedure of Indoor Unit 79 11 2 Removal Procedure of Outdoor Unit 18K 86 11 3 Removal Procedure of Outdoor U...

Страница 4: ...nual 1 Summary Part Technical Information Indoor Unit GWH18RC K3DNA2C I GWH24RD K3DNA2C I GWH18RC K3DNA3C I GWH24RD K3DNA3C I GWH18RC K3DNA8C I GWH24RD K3DNA8C I GWH18RC K3DNA6C I GWH24RD K3DNA6C I GW...

Страница 5: ...ical Information Service Manual GWH18RC K3DNA3C O Outdoor Unit Remote Controller YAA1FB GWH18RC K3DNA8C O GWH24RD K3DNA8C O GWH24RD K3DNA3C O GWH18RC K3DNA9C I white panel GWH18RC K3DNA9C I silver gre...

Страница 6: ...ndoor Unit Model of indoor unit 1 GWH18RC K3DNA3C I 2 GWH18RC K3DNA2C I 3 GWH18RC K3DNA6C I 1 GWH24RD K3DNA3C I 2 GWH24RD K3DNA2C I 3 GWH24RD K3DNA6C I Fan Type URVV RZ URVV RZ Diameter Length DXL mm...

Страница 7: ...tput of Fan Motor W 60 90 Fan Motor RLA A 0 58 0 48 Fan Motor Capacitor Air Flow Volume of Outdoor Unit m3 h 3200 4000 Fan Type LDO RZ LDO RZ Fan Diameter mm Defrosting Method Automatic Defrosting Aut...

Страница 8: ...GWH18RC K3DNA8C I GWH18RC K3DNA5C I GWH24RD K3DNA8C I GWH24RD K3DNA5C I Fan Type URVV RZ URVV RZ Diameter Length DXL mm Fan Motor Cooling Speed SH H M L SL r min 1350 1200 1000 800 1350 1150 950 850...

Страница 9: ...780 Output of Fan Motor W Fan Motor RLA A Fan Motor Capacitor Air Flow Volume of Outdoor Unit m3 h 3200 4000 Fan Type LDO RZ LDO RZ Fan Diameter mm Defrosting Method Automatic Defrosting Automatic De...

Страница 10: ...34 Indoor Unit Model of indoor unit GWH18RC K3DNA9C I white panel GWH18RC K3DNA9C I silver grey panel Fan Type URVV RZ Diameter Length DXL mm Fan Motor Cooling Speed SH H M L SL r min 1350 1200 1000...

Страница 11: ...Capacitor Air Flow Volume of Outdoor Unit m3 h 3200 Fan Type LDO RZ Fan Diameter mm Defrosting Method Automatic Defrosting Climate Type T1 Isolation I Moisture Protection IP24 Permissible Excessive O...

Страница 12: ...24 C Indoor air flow Super High Pipe length 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow Super High Pipe length 5m Compressor speed rps Compressor speed rps Cooling Heating 3...

Страница 13: ...ipe connecting indoor and outdoor unit Inlet and outlet pipe temperature of heat exchanger Fan speed of indoor unit Fan speed of outdoor unit Compressor revolution rps Indoor Outdoor P MPa T1 T2 27 19...

Страница 14: ...formation Service Manual 3 Outline Dimension Diagram 3 1 Indoor Unit D W 57 38 144 95 60 194 116 189 694 685 H Model W H D A9 panel 18K 945 298 205 Other panel 18K 945 298 208 24K 1018 315 223 18K 24K...

Страница 15: ...12 Technical Information Service Manual 1000 920 610 790 395 370 427 965 892 700 396 560 341 396 3 2 Outdoor Unit Model GWH18RC K3DNA3C O Unit mm Unit mm Model GWH24RD K3DNA3C O...

Страница 16: ...13 Installation and Maintenance Service Manual 427 1000 920 610 370 790 395 340 965 700 396 890 560 364 Unit mm Unit mm GWH18RC K3DNA8C O GWH24RD K3DNA8C O...

Страница 17: ...Q SLSH VSHFL FDWLRQ Liquid pipe 1 4 6mm Gas pipe 1 2 12mm 18K Gas pipe 5 8 16mm 24K Indoor unit Outdoor unit COOLING HEATING 4 Way valve Discharge Suction Heat exchanger evaporator Heat exchanger cond...

Страница 18: ...N Green CAP Jumper cap YE Yellow BN Brown COMP Compressor RD Red BU Blue Grounding wire YEGN Yellow Green BK Black VT Violet OG Orange Note Jumper cap is used to determine fan speed and the swing angl...

Страница 19: ...WING UD M2 TUBE ROOM PE BK AC L TEMP SENSOR TEMP SENSOR 0 COLDPLASMA GENERATOR HEALTH L HEALTH N RD BU TERMINAL BLOCK L L SWING C0NNECTING CABLE EVAPORATOR 3 2 BU BK BN YEGN PRINTED CIRCUIT BOARD DISP...

Страница 20: ...2 L2 OVC COMP WH WH SAT YEGN COMP BK BN BU X1 TERMINAL COMP COMP U COMP V COMP W INDC2 OG WH INDC1 L OUTTUBE TEMP SENSOR OUTROOM TEMP SENSOR EXHAUST TEMP SENSOR PE BLOCK OVERLOAD PROTECTOR L3 L3 RING...

Страница 21: ...30V to prevent the risk of electric shock 3 203 These wiring diagrams are subject to change without notice please refer to the one supplied with the unit Model GWH18RC K3DNA8C O 1 3OHDVH GRQ W WRXFK...

Страница 22: ...re 4 Interface of neutral wire for health function 5 Control interface of PG motor 6 Interface of live wire for health function 7 Interface of indoor unit and outdoor unit communication 8 Auto button...

Страница 23: ...perature sensor 3 Terminal of compressor overload protection 4 Terminal of outdoor temperature sensor 5 Terminal of electronic expansion valve 6 Terminal of outdoor fan 7 Terminal of 4 way valve 8 Wir...

Страница 24: ...ction 4 Terminal of outdoor temperature sensor 5 Terminal of electronic expansion valve 6 Terminal of outdoor fan 7 Terminal of 4 way valve 8 Communication wire with indoor unit 9 Power supply live wi...

Страница 25: ...Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Clock Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel X fan mode health function Note IWHU SXWWLQJ WKURXJK WKH SRZHU...

Страница 26: ...hanges as below This remote controller is universal If any command or is sent out the unit will carry out the command as indicates the guide louver swings as 7 I FEEL Button Press this button to turn...

Страница 27: ...rn on the display s light and press this button again to turn off the display s light If the light is turned on is displayed If the light is turned off disappears 16 X FAN Button Pressing X FAN button...

Страница 28: ...HPRWH FRQWUROOHU LV IX RU WKHUH V QR GLVSOD SOHDVH UHSODFH batteries If remote controller is lost or damaged please use auxiliary button to turn on or turn RII WKH DLU FRQGLWLRQHU 7KH RSHUDWLRQ LQ GHW...

Страница 29: ...r will rotate to the horizontal position L The indoor fan will be stopped after operating for 60s at setting speed b Due to the blockage of PG motor horizontal louver will keep the stop position when...

Страница 30: ...operated for 7 hours the temperature will decrease by 1o C and then the unit will operate at this temperature all the time 3 When the initial temperature is set as 28 29o C after starting up the sleep...

Страница 31: ...t and the system will operate according to the latest setting When the unit is on and Timer ON and Timer OFF are both set the system will operate according to the set state When the timer off time is...

Страница 32: ...satisfied if the temperature for defrosting is satisfied after detections for continuous 3minutes the defrosting operation will start 2 Start to defrost Compressor stops and starts up 55S later 1 Tout...

Страница 33: ...overload protection is resumed and compressor has stopped for 3min the unit will be allowed to operate 3 If the unit stops as compressor overload protection occurred for 3 times continuously it can no...

Страница 34: ...nit adequately grounded The grounding wire can t be used for other purposes 6 Must apply protective accessories such as protective boards cable cross loop and wire clip 7 The live wire neutral wire an...

Страница 35: ...ng tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 T...

Страница 36: ...least 15cm At least 15cm At least 15cm At least 250cm Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wall...

Страница 37: ...or unit Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installat...

Страница 38: ...ing with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding...

Страница 39: ...position of piping hole should be a little lower than the wall mounted frame As show in Fig 1 5 Connect the Pipe of Indoor Unit 1 Aim the pipe joint at the corresponding bellmouth As show in Fig 5 2 P...

Страница 40: ...ig 14 2 Reserve a certain length of drain hose and power cord for installation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in...

Страница 41: ...r unit select it according to the actual installation situation 1 Select installation location according to the house structure 2 Fix the support of outdoor unit on the selected location with expansio...

Страница 42: ...Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent 2 Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then connec...

Страница 43: ...oor unit and then remove the cover of electric box V VKRZQ LQ WKH J EHORZ FRQQHFW WKH SOXJ RI GLVFKDUJH UHVLVWDQFH DERXW RKP LI WKHUH LV QR GLVFKDUJH UHVLVWDQFH you can use the plug of soldering iron...

Страница 44: ...nd drying operation compressor and outdoor fan stop while indoor fan operates During heating operation all loads stop Please refer to the malfunction analysis discharge protection overload 3 Overcurre...

Страница 45: ...compressor stops while indoor fan will operate During heating operation the complete unit will stop operation Outdoor temperature sensor hasnt been connected well or is damaged Please check it by ref...

Страница 46: ...ring heating operation the complete unit will stop operation Refer to the malfunction analysis IPM protection loss of synchronism protection and overcurrent protection of phase current for compressor...

Страница 47: ...imes During cooling and drying operation compressor will stop while indoor fan will operate During heating operation the complete unit will stop Supply voltage is unstable 28 Voltage of DC bus bar is...

Страница 48: ...EU Over load normal works compressor runing frequency declines Whole unit break for 20 mins and discharge check the outdoor control board AP1 s IPM module coolant whether is short the radiator is tig...

Страница 49: ...ller loosened or poorly contacted Insert the temperature sensor tightly yes Is malfunction eliminated Is there short circuit due to trip over of the parts Make the parts upright yes Is malfunction eli...

Страница 50: ...al of PG motor tightly no no Stir the blade by hand to see whether the blade rotate s smoothly Reinstall the blade and motor correctly Is malfunction eliminated no no yes yes Turn on the unit again me...

Страница 51: ...er cap inserted correctly and tightly Replace the jumper cap with the same model End yes yes Assemble the jumper cap with the same model no Is malfunction eliminated no yes Insert the jumper cap tight...

Страница 52: ...shell too high etc Is the indoor outdoor heat exchanger too dirty or are the air inlet and outlet blocked Normal fluctuation is within 10 of the rated voltage on the nameplate Malfunction is eliminate...

Страница 53: ...e unit returns to normal Conclusion U8 is displayed due to instant energization afte de energization while the capacitor discharges slowly The zero cross detection circuit of the mainboard is defined...

Страница 54: ...tage higher than 200V Malfunction of the outdoor mainboard AP1 Replace outdoor mainboard Measure the voltage input with AC voltmeter see fig 30 Voltage within 180VAC 260VAC Shut down the power and wai...

Страница 55: ...H ZRUN ORDG RI XQLW LV KHDY I UDGLDWLQJ RI XQLW LV JRRG Malfunction diagnosis process N N Y N Y Y Y N N N N N Y Y Y Y Y H5 H7 or P5 is displayed after turning on the unit Measure if the voltage input...

Страница 56: ...E8 is displayed If the outdoor ambient temperature is higher than 53 Normal protection please use it after improving the outdoor ambient temperature Unit restarts normally Unit restarts normally If th...

Страница 57: ...ent and the high and low pressure of system is not balanced please start the unit after 3min If the compressor wire COMP UVW is well connected and connection sequence is correct Check the connection s...

Страница 58: ...RQ YDOYH GDPDJHG I WKH UHIULJHUDQW LV OHDNHG 7KH FRPSUHVVRU RYHUORDG SURWHFWLRQ WHUPLQDO LV QRW FRQQHFWHG ZHOO ZLWK WKH PDLQERDUG I WKH RYHUORDG SURWHFWRU LV GDPDJHG HDW H FKDQJH RI XQLW LV QRW JRRG K...

Страница 59: ...rigerant according to the service manual Compressor overload protection terminal is not connected well with the mainboard reconnect them correctly Heat exchange of unit is not good heat exchanger is d...

Страница 60: ...well with the socket Connect the plug correctly Check the connection wire between reactor mainboard and situation of connection If there is short circuit or the connection wire is loose Reconnect the...

Страница 61: ...unit operates normally before malfunction Check built in wiring of indoor and outdoor unit If the wiring is damaged Replace the wire Check the malfunction type with communication malfunction detector...

Страница 62: ...ls Malfunction of compressor Compressor can t operate Refer to point 5 of maintenance method for details 9 4 Troubleshooting for Normal Malfunction 1 Air Conditioner Can t be Started Up 2 Poor Cooling...

Страница 63: ...drain pipe Replace drain pipe Wrapping is not tight Water leaking from the pipe connection place of indoor unit wrap it again and bundle it tightly 5 Compressor Can t Operate Possible causes Discrimi...

Страница 64: ...61 Installation and Maintenance Service Manual 10 Exploded View and Parts List 10 1 Indoor Unit 1 Models GWH18RC K3DNA3C I GWH18RC K3DNA2C I GWH18RC K3DNA5C I...

Страница 65: ...02937 01002937 1 17 Evaporator Support 24212133 24212133 24212133 1 18 Pipe Clamp 2611216401 2611216401 2611216401 1 19 Motor Press Plate 26112494 26112494 26112494 1 20 Fan Motor 15012146 15012146 15...

Страница 66: ...63 Installation and Maintenance Service Manual 2 Models GWH18RC K3DNA8C I GWH18RC K3DNA6C I...

Страница 67: ...4212133 24212133 1 18 Connecting pipe clamp 2611216401 2611216401 1 19 Motor Press Plate 26112494 26112494 1 20 Fan Motor 15012146 15012146 1 21 Wall Mounting Frame 01252218 01252218 1 22 Drainage Hos...

Страница 68: ...65 Installation and Maintenance Service Manual 3 Models GWH18RC K3DNA9C I white panel GWH18RC K3DNA9C I silver grey panel 1 10...

Страница 69: ...pport 24212133 26152022 1 16 Pipe Clamp 2611216401 01002937 1 17 Motor Press Plate 26112494 24212133 1 18 Fan Motor 15012146 2611216401 1 19 Wall Mounting Frame 01252218 26112494 1 20 Drainage hose 05...

Страница 70: ...67 Installation and Maintenance Service Manual 4 Models GWH24RD K3DNA2C I GWH24RD K3DNA3C I 37 34 33 35 36 1 2 3 4 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 25 26 27 28 29 30 32 5 24 10 31...

Страница 71: ...Frame 01252032 01252032 1 16 Motor Press Plate 26112316 26112316 1 17 Fan Motor 15012098 15012098 1 18 Pipe Clamp 2611218801 2611218801 1 19 Drainage hose 0523001405 0523001405 1 20 Step Motor 1521300...

Страница 72: ...allation and Maintenance Service Manual 37 38 34 33 35 36 1 2 3 4 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 25 26 27 28 29 30 32 5 24 10 31 5 Models GWH24RD K3DNA8C I GWH24RD K3DNA6C I GWH24RD K3...

Страница 73: ...16 26112316 26112316 1 17 Fan Motor 15012098 15012098 15012098 1 18 Pipe Clamp 2611218801 2611218801 2611218801 1 19 Drainage hose 0523001405 0523001405 0523001405 1 20 Step Motor 1521300101 152130010...

Страница 74: ...71 Installation and Maintenance Service Manual 10 2 Outdoor Unit 1 Model GWH18RC K3DNA3C O...

Страница 75: ...assy 01715010P 1 12 Right Side Plate 0130509402P 1 13 Valve cover 22245002 1 14 Handle 26235254 1 15 Wiring Clamp 26115004 1 16 Rear Grill 01473043 1 17 Condenser Assy 0116348702 1 18 Reactor 4313002...

Страница 76: ...73 Installation and Maintenance Service Manual 2 Model GWH18RC K3DNA8C O...

Страница 77: ...02P 1 13 Valve cover 22245002 1 14 Handle 26233053 1 15 Wiring Clamp 26115004 1 16 Rear Grill 01473043 1 17 Condenser Assy 01163487 1 18 Reactor 43130025 1 19 Clapboard Assy 01233153 1 20 Coping 01255...

Страница 78: ...75 Installation and Maintenance Service Manual 3 Model GWH24RD K3DNA3C O...

Страница 79: ...14 Cut off Valve 07133157 1 15 DI H 9DOYH 6XSSRUW 01365435P 1 16 Right Side Plate 0130504401P 1 17 Valve Cover 22245003 1 18 Big Handle 26235001 1 19 Wiring Clamp 26115004 1 20 Rear Grill 01475013 1 2...

Страница 80: ...77 Installation and Maintenance Service Manual 4 Model GWH24RD K3DNA8C O...

Страница 81: ...133157 1 15 DI H 9DOYH 6XSSRUW 01365435P 1 16 Right Side Plate 0130504401P 1 17 Valve cover 22245003 1 18 Big Handle 26235001 1 19 Wiring Clamp 26115004 1 20 Rear Grill 01475013 1 21 Condenser Assy 01...

Страница 82: ...moval Procedure of Indoor Unit Caution discharge the refrigerant completely before removal 2 1 2 Remove the filter Open the front panel filter 1 Before disassembly Before disassembly Push the filter u...

Страница 83: ...axile bush on the horizontal louver Pull the horizontal louver outward to remove it 4 Remove the panel axile bush horizontal louver panel display Loosen the screws fixing the indicator Remove the indi...

Страница 84: ...move the electric box cover Loosen the screw of the electric box cover Remove the electric box cover Remove the front case Open the screw cap on the front case Remove the screws fixing the front case...

Страница 85: ...Remove the vertical louver Loosen the 10 clasps connecting the vertical louver and bottom case subassembly Remove the vertical louver 8 Remove the electric box subassembly Disconnect the indoor tube t...

Страница 86: ...Loosen the clasp at the joint of the electric box cover and the electric box Disconnect the wiring terminal of the motor and step motor on the electric box Loosen the screws fixing the electric box an...

Страница 87: ...Clamp Auxiliary piping 1 1 2 9 Remove press plate of connecting pipe Remove the screws of the press plate of connecting pipe Remove press plate of connecting pipe 10 Remove the evaporator Remove the s...

Страница 88: ...pipe slightly to separate the connecting pipe and the evaporator Remove the evaporator 11 Remove motor and cross flow fan Remove the screw of the step motor and remove the step motor Remove the screw...

Страница 89: ...e differences Remove the screw connecting the big handle and right side plate and then remove the big handle Remove the screw connecting the valve cover and right side plate and then remove the valve...

Страница 90: ...ft side plate and then remove the outer case Remove the 3 screws connecting the grille with right side plate and left side plate and then remove the rear guard grille Remove the screws connecting the...

Страница 91: ...the grounding wire screw on the electric box assy and then remove the JURXQGLQJ ZLUH 6HH J a c b Disconnect the wiring terminals of reactor compressor high and low pressure switch compressor overload...

Страница 92: ...upwards to remove it d e f g Push the electric box cover in the direction of arrow to make the clasp at the right side separate from the groove then pull it in the opposite direction to make the clasp...

Страница 93: ...the 3 screws connecting the isolation plate and chassis and then remove the isolation plate Remove the 4 screws connecting the reactor and isolation plate and then remove the reactor reactor isolatio...

Страница 94: ...welding joint wrap the gas valve with a wet cloth completely to avoid damage to the valve caused by high temperature bolts liquid valve gas valve 9 Remove 4 way valve assy Remove the 2 screws connect...

Страница 95: ...12 Remove compressor 5HPRYH WKH IRRW QXWV LQJ FRPSUHVVRU DQG then lift the compressor upwards to remove the compressor and damping cushion Note Keep the ports of discharge pipe and suction pipe from f...

Страница 96: ...panel front side plate 2 Remove grille Twist off the screws connecting the grille and panel and then remove the grille grille valve cover Use the screwdriver to remove the screws connecting the top pa...

Страница 97: ...connecting the panel chassis and motor support with screwd river and then remove the panel 4 Remove guard grille Twist off the screws fixing the guard grille and then remove the guard grille 5 Remove...

Страница 98: ...nd condenser and then remove the right side plate Twist off the screws on electric box cover with screwdriver and then remove the electric box cover Twist off the screws on electric box cut off the ti...

Страница 99: ...late axial flow blade Twist off the screws between electric box 1 and left side plate with screw driver pull it upwards to remove the electric box 1 Twist off the screws connecting the left side plate...

Страница 100: ...f the tapping screws fixing the motor pull out the pin of leading wire for motor and then remove the motor Twist off the tapping screws fixing the motor support pull it upwards and then remove the mot...

Страница 101: ...dering the soldering joint wrap the gas valve with wet cloth completely to avoid the damage to valve and release all refrigerant completely at first Unsolder the soldering joint between liquid valve a...

Страница 102: ...of condenser chassis 15 Remove support plate of condenser Twist off the screws connecting the support plate of condenser and condenser with screwdriver and then remove the support plate of condenser...

Страница 103: ...renheit Celsius 32 33 32 0 55 56 55 4 13 79 80 78 8 26 34 35 33 8 1 57 58 57 2 14 81 80 6 27 36 35 6 2 59 60 59 15 82 83 82 4 28 37 38 37 4 3 61 62 60 8 16 84 85 84 2 29 39 40 39 2 4 63 62 6 17 86 87...

Страница 104: ...pipe according to the following steps A Cut the pip RQ UP WKH SLSH OHQJWK DFFRUGLQJ WR WKH GLVWDQFH RI LQGRRU XQLW DQG RXWGRRU XQLW XW WKH UHTXLUHG SLSH ZLWK SLSH FXWWHU B Remove the burrs 5HPRYH WKH...

Страница 105: ...58 6 66 88 33 10 63 72 2 439 111 0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77...

Страница 106: ...11 0 983 5 84 61 34 13 59 73 3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 7...

Страница 107: ...3 53 74 62 11 32 101 3 22 15 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2...

Страница 108: ...d Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 Email gree gree com cn Http www gree com HONG KONG GREE ELECTRIC APPLIANCES SALES LIMITED Add Unit 2612 26 F Miramar Towe...

Отзывы: