92
Installation and Maintenance
Service Manual
Motor clamp
10. Remove motor and cross flow blade
a
b
Remove the screws fixing motor clamp
and then remove the motor clamp.
Remove the screw at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
Motor
Screw
C
ross flow
c
Remove the bearing holder sub-assy.
Holder sub-assy
Bottom case
Remove the screw fixing step motor and
then remove the step motor.
Step motor
9. Remove stepping motor
Procedure
Steps
Screws