Installation Manual
38
7. Installation Manual
7.1 Notices for Installation
Caution
1.The unit should be installed only by authorized service center according to local or government regulations and in compliance with
this manual.
2.Before installing, please contact with local authorized maintenance center. If the unit isnot installed by the authorized ser vice center,
the malfunction may not be solved due to incovenient contact between the user and the service personnel.
3.When removing the unit to the other place, please firstly contact with the local authorized service center.
4.Warning: Before obtaining access to terminals, all supply circuits must be disconnected.
5.For appliances with type Y attachment, the instructions shall contain the substance of the following. If the supply cord is damaged,
it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
6.The appliance must be positioned so that the plug is accessible.
7.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube.
8.The instructions shall state the substance of the following:
This appliance is not intended for use by persons(including children)with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
7.1.1
Installation Site Instructions
Proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where:
strong heat sources, vapours, flammable gas or volatile liquids are emitted.
high-frequency electro-magnetic waves are generated by radio equipment,welders and medical equipment.
salt-laden air prevails (such as close to coastal areas).
the air is contaminated with industrial vapours and oils.
the air contains sulphures gas such as in hot spring zones.
corrosion or poor air quality exists.
7.1.2
Installation Site of Indoor Unit
1.The air inlet and outlet should be away from the obstructions. Ensure the air can be blown through the whole room.
2.Select a site where the condensate can be easily drained out, and where it is easily connected to outdoor unit.
3.Select a place where it is out of reach of children.
4.Select a place where the wall is strong enough to withstand the full weight and vibration of the unit.
5.Be sure to leave enough space to allow access for routine maintenance. The installation site should be 250cm or more above th e
floor.
6.Select a place about 1m or more away from TV set or any other electric appliance.
7.Select a place where the filter can be easily taken out.
8.Make sure that the indoor unit is installed in accordance with installation dimension instructions.
9.Do not use the unit in the laundry or by swimming pool etc.