12
Technical Information
Service Manual
remote controller.
②
Only when the remote control signal is switched to indoor ambient temperature display status from other display status, controller will
display the indoor ambient temperature
for 3s and then turn back to display the setting temperature.
③
When user hasnt set the temperature displaying status, it will be displayed according to the setting temperature.
(2)Malfunction Display of Indoor Unit
When multiple malfunctions occurred simultaneously, malfunction protection codes will be displayed in cycle.
3.Other Control Target
(1) Up&down swing function
After energization, up & down swing motor will firstly let the horizontal louver anticlockwise rotate to position 0 to close air outlet.
If swing function has not been set after startup of the unit, up & down horizontal louver will clockwise turn to position D in HEAT mode,
or clockwise turn to level position L in other modes.
If setting swing function while starting up the unit, the horizontal louver will swing between L and D.
There are 7 kinds of swing status of horizontal louver: Positions L, A, B, C and D, swing between L and D and stop at any position
between L and D.
Upon turning off the unit, the horizontal louver will close at position 0. Swing function is available only when swing
function set and indoor fan is operating.
Note: If the position is set between L and B, A and C or B and D by remote controller, the horizontal louver will swing between L and D.
L----A----B----C----D
(2) Buzzer
Upon energization and operation, the buzzer will give out sound.
(3) Auto Button
After pressing this button, the unit will operate in auto mode. Indoor fan will operate at auto fan speed and swing motor will operate.
Press this button again to turn off the unit. The complete unit is energized when pressing the button and the complete unit will enter into
fast testing status. After energization, if its detected that the auto button is pressed down and the complete unit is at fast testing status,
the fast testing status will be exited.
(4) Sleep Function
This mode is only valid in cooling and heating mode. The unit will select the appropriate sleeping curve to operate according to the
different setting temperature.
During cooling mode:
①
When the initial temperature is set as 16~23°C, after starting up the sleep function, the temperature will increase by1°C every one
hour.After the temperature has increased by 3°C, the unit will keep this temperature. When the unit has operated for 7 hours, the
temperature will decrease by 1°C and then the unit will operate at this temperature all the time;
②
When the initial temperature is set as 24~27°C, after starting up the sleep function, the temperature will increase by1°C every one
hour.After the temperature has increased by 2°C, the unit will keep this temperature. When the unit has operated for 7 hours, the
temperature will decrease by 1°C and then the unit will operate at this temperature all the time;
③
When the initial temperature is set as 28~29°C, after starting up the sleep function, the temperature will increase by1°C every one
hour.After the temperature has increased by 1°C, the unit will keep this temperature. When the unit has operated for 7 hours, the
temperature will decrease by 1°C and then the unit will operate at this temperature all the time;
④
When the initial temperature is set as 30°C, the unit will operate at this temperature. After the unit has operate for 7hours, the
temperature will decrease by 1°C and then the unit will operate at this temperature all the time.
During Heating Mode:
①
When the initial temperature is set at 16°C, the unit will operate at this temperature all the time;
②
When the initial temperature is set as 17~20°C, after starting up the sleep function, the temperature will decrease by1°C every one
hour.After the temperature is decreased by 1°C, the unit will operate at this temperature;
③
When the initial temperature is set as 21~27°C, after starting up the sleep function, the temperature will decrease by1°C every one
hour.After the temperature is decreased by 2°C, the unit will operate at this temperature;
④
When the initial temperature is set as 28~30°C, after starting up the sleep function, the temperature will decrease by1°C every one
hour.
After the temperature is decreased by 3°C, the unit will operate at this temperature;
General timer and clock timer functions are compatible by equipping different functions of remote controller.
(5) Timer Function
General timer and clock timer functions are compatible by equipping different functions of remote controller.
General timer:
Timer ON
If timer ON is set during operation of the unit, the unit will continue to operate. If timer ON is set at unit OFF, upon ON time reaches the
unit will start to operate according to previous setting status.
Timer OFF
If timer OFF is set at unit OFF, the system will keep standby status. If timer OFF is set at unit ON, upon OFF time reaches the unit will
stop operation.