84
Installation and Maintenance
Service Manual
6.Remove soundproof sponge
Since the piping ports on the soundproof sponge are
torn easily, remove the soundproof sponge carefully
soundproof sponge
7. Remove
Isolation sheet
Remove the 3 screws fixing the isolation sheet
and then remove the Isolation sheet.
Isolation sheet
8. Remov e 4-way valve assy
Discharge the refrigerant completely;unsolder
the pipelines connecting the compressor and
the condenser assy,and then remove the 4-way
valve assy.
4-way valve assy
Steps