![Gree GWH09RB-K3DNA2C Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/gree/gwh09rb-k3dna2c/gwh09rb-k3dna2c_service-manual_2260522084.webp)
81
Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
1.
2
Handle
2.
Top panel
1
Remove big handle
Before disassembly
Remove 1 connection screw fixing big
hand leand then remove the big handle.
Remove top cover plate
Remove 3 connection screws among
top cover plate, front panel and right
sideplate. Then remove top cover
plate.
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Take GWH09RB-K3DNA3C/O(CB302W00900), GWH12RB-K3DNA3C/O(CB302W01000) for example.