![Gree GWH09RB-K3DNA2C Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/gree/gwh09rb-k3dna2c/gwh09rb-k3dna2c_service-manual_2260522016.webp)
13
Technical Information
Service Manual
2.4 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(
℃
) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe temperature
of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(Hz)
Indoor
Outdoor
P (MPa)
T1 (
℃
)
T2 (
℃
)
27/19
35/24
09K
0.85~1.0
in:8~11
out:11~14
in:50~80
out:37~43
Turbo
Suprt High
49
12K
68
Rated cooling
condition(
℃
) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat exchanger Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(Hz)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/-
7/6
09K
2.5~3.0
in:50~80
out:37~43
in:1~3
out:2~5
Turbo
Suprt High
54
12K
71
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Cooling:
Heating:
2.5 Noise Curve
45
35
25
Indoor side noise when blowing
Indoor fan motor rotating speed
Low
Middle
High
12K
40
42
44
46
48
50
52
54
20
40
30
50
60
70
80
Compressor frequency(Hz)
Noise dB(A)
Noise dB(A)
Heating
Cooling
09K