19
Technical Information
Service Manual
6.2 Brief Description of Modes and Functions
1. Temperature Parameters
ƹ
,QGRRUSUHVHWWHPSHUDWXUH7SUHVHW
ƹ
,QGRRUDPELHQWWHPSHUDWXUH7DPE
2. Basic Functions
2QFHHQHUJL]HGLQQRFDVHVKRXOGWKHFRPSUHVVRUEHUHVWDUWHGZLWKLQOHVVWKDQPLQXWHV,QWKHVLWXDWLRQWKDWPHPRU\IXQFWLRQ
LVDYDLODEOHIRUWKH¿UVWHQHUJL]DWLRQLIWKHFRPSUHVVRULVDWVWRSEHIRUHGHHQHUJL]DWLRQWKHFRPSUHVVRUZLOOEHVWDUWHGZLWKRXWD
PLQXWHODJLIWKHFRPSUHVVRULVLQRSHUDWLRQEHIRUHGHHQHUJL]DWLRQWKHFRPSUHVVRUZLOOEHVWDUWHGZLWKDPLQXWHODJDQGRQFH
VWDUWHGWKHFRPSUHVVRUZLOOQRWEHVWRSSHGZLWKLQPLQXWHVUHJDUGOHVVRIFKDQJHVLQURRPWHPSHUDWXUH
(1) Cooling Mode
ķ
Working conditions and process of cooling
Cooling conditions and process(09k)
a.
:KHQ7DPE7SUHVHWWKHXQLWVWDUWVFRROLQJ,QWKLVFDVHWKH,'8IDQPRWRU2'8IDQPRWRUDQGFRPSUHVVRUUXQDQGWKH,'8IDQ
PRWRUUXQVDWVHWVSHHG
E:KHQ7DPE 7SUHVHW
ć
WKHFRPSUHVVRUFRQWLQXRXVO\RSHUDWHVEHORZWKHIUHTXHQF\RI+]QRWLQ]IRUPLQV,I
7DPE 7VHW
ć
VWLOONHHSVWKHVDPHWKHFRPSUHVVRUVWRSVRSHUDWLRQ
c.
:KHQ7DPE7SUHVHW
ć
WKHFRPSUHVVRUVWRSVRSHUDWLRQ2'8IDQPRWRUVWRSVRSHUDWLRQZLWKDGHOD\RIVDQG,'8IDQPRWRU
RSHUDWHVDWVHWVSHHG
d.
:KHQ7SUHVHW
ć˘
7DPE
˘
7VHWWKHXQLWZLOOPDLQWDLQLWVSUHYLRXVUXQQLQJVWDWXV
Cooling conditions and process(12k)
D:KHQ7DPE7LQGRRU VXSSOHPHQWDU\7SUHVHW WKH XQLW VWDUWV FRROLQJ ,Q WKLV FDVH WKH ,'8 IDQ PRWRU 2'8 IDQ PRWRU DQG
FRPSUHVVRUUXQDQGWKH,'8IDQPRWRUUXQVDWVHWVSHHG
E:KHQ7DPE7LQGRRUVXSSOHPHQWDU\7SUHVHW
ć
WKHFRPSUHVVRUVWRSVRSHUDWLRQ2'8IDQPRWRUVWRSVRSHUDWLRQZLWKDGHOD\
RIVDQG,'8IDQPRWRURSHUDWHVDWVHWVSHHG
F:KHQ7SUHVHW
ć˘
7LQGRRUDPE7LQGRRUVXSSOHPHQWDU\
˘
7SUHVHWWKHXQLWZLOOPDLQWDLQLWVSUHYLRXVUXQQLQJVWDWXV
8QGHUWKLVPRGHWKHIRXUZD\YDOYHZLOOEHGHHQHUJL]HGDQGWHPSHUDWXUHFDQEHVHWZLWKLQDUDQJHIURPWR
o
C.
,IWKHFRPSUHVVRULVVKXWGRZQIRUVRPHUHDVRQWKHLQGRRUIDQDQGWKHVZLQJGHYLFHZLOORSHUDWHDWRULJLQDOVWDWH
ĸ
Protection
ƹ
Antifreeze protection
8QGHUFRROLQJDQGGHKXPLGLI\LQJPRGHPLQXWHVDIWHUWKHFRPSUHVVRULVVWDUWHG
,I7HYDS
o
&WKHFRPSUHVVRUZLOORSHUDWHDWUHGXFHGIUHTXHQF\
,I7HYDS
o
&LVGHWHFWHGIRUGXUDWLYHPLQXWHVWKHFRPSUHVVRUZLOOVWRSDQGDIWHUVHFRQGVWKHRXWGRRUIDQZLOOVWRSDQGXQGHU
FRROLQJPRGHWKHLQGRRUIDQDQGWKHVZLQJPRWRUZLOOUHPDLQDWWKHRULJLQDOVWDWH
,I7HYDS
o
&DQGWKHFRPSUHVVRUKDVUHPDLQHGDW2))IRUDWOHDVWPLQXWHVWKHFRPSUHVVRUZLOOUHVXPHLWVRULJLQDORSHUDWLRQ
state.
ƹ
Total current up and frequency down protection
If I
total
IUHTXHQF\ULVHZLOOEHDOORZHGLI,
total
IUHTXHQF\ULVHZLOOQRWEHDOORZHGLI,
total
WKHFRPSUHVVRUZLOOUXQDWUHGXFHG
IUHTXHQF\DQGLI,
total
WKHFRPSUHVVRUZLOOVWRSDQGWKHRXWGRRUIDQZLOOVWRSZLWKDWLPHODJRIV
(2) Dehumidifying Mode
ķ
Working conditions and process of dehumidifying
,I7DPE!7SUHVHWWKHXQLWZLOOHQWHUFRROLQJDQGGHKXPLGLI\LQJPRGHLQZKLFKFDVHWKHFRPSUHVVRUDQGWKHRXWGRRUIDQZLOORSHUDWH
DQGWKHLQGRRUIDQZLOOUXQDWORZVSHHG
If Tpreset -2
o
&7DPE7SUHVHWWKHFRPSUHVVRUUHPDLQVDWLWVRULJLQDORSHUDWLRQVWDWH
,I7DPE7SUHVHW
o
&WKHFRPSUHVVRUZLOOVWRSWKHRXWGRRUIDQZLOOVWRSZLWKDWLPHODJRIVDQGWKHLQGRRUIDQZLOORSHUDWHDW
low speed.
ĸ
Protection
3URWHFWLRQLVWKHVDPHDVWKDWXQGHUWKHFRROLQJPRGH
(3) Heating Mode
Содержание GWH09QB-K3DNA1D
Страница 47: ...44 Installation and Maintenance Service Manual...