7URXEOHVKRRWLQJ
2YHUORDG DQG DLU H[KDXVW PDOIXQFWLRQ GLDJQRVLV IROORZLQJ $3 IRU RXWGRRU XQLW FRQWURO ERDUG
0DLQO\ GHWHFW
Ɣ,V WKH 309 FRQQHFWHG ZHOO RU QRW" ,V 309 GDPDJHG"
Ɣ,V UHIULJHUDQW OHDNHG"
)DXOW GLDJQRVLV SURFHVV
20 minutes after the
complete unit is
powered off
Is the terminal FA for the
electronic expansion valve
connected correctly?
Connect the
wires correctly
Resistances between the first four pins
close to the terminal hole and the fifth
pin are almost the same, less than 100
ohm.
Replace the electronic
expansion valve
If the fault is eliminated?
If the fault is eliminated?
Replace the
control panel
AP1
Coolant leakage, refilling
the coolant
End