203
Disassembly of Outdoor Unit
36K 240 volt unit shown, other models may vary slightly
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove the two bolts holding the valve sub assem-
bly. Unsolder the solder joint between gas valve and
air-return pipe and then remove the gas valve (Note:
when un-soldering the soldering joint, wrap the gas
valve with wet cloth completely to avoid the damage
to valve, and release all refrigerant completely at
first). Unsolder the soldering joint between liquid
valve and connection pipe of liquid valve, and then
remove the liquid valve.
Remove the three foot-nuts on the compressor and
then remove the compressor.
13. Remove compressor
Remove the screws connecting isolation sheet and
end plate of condenser and chassis, and then re-
move the isolation sheet.
14. Remove isolation sheet
12. Remove gas and liquid valve