background image

21

Malfunction analysis

Phenomenon

Check items

Solution

Odours are 

emitted

● Whether there’s odour source,

   such as furniture and cigarette, 

   etc.

● Eliminate the odour source.
● Clean the filter.

“Water 

flowing” 

noise

● Air conditioner is turned on or

   turned off just now?

● The noise is the sound of 

   refrigerant flowing inside 

   the unit, which is a normal

   phenomenon.

Cracking 

noise

● Air conditioner is turned on or

   turned off just now?

● This is the sound of friction 

   caused by expansion and/or

   contraction of panel or other 

   parts due to the change of

   temperature.

Air conditio-

ner operates 

abnormally 

suddenly

● Whether there’s interference,

   such as thunder, wireless 

   devices, etc.

● Disconnect power, put back 

   power, and then turn on the 

   unit again.

Содержание GWH07QB-K3DNA1G/I

Страница 1: ...r choosing our product If you have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper operation please r...

Страница 2: ...K3DNA2G I GWH12QC K3DNB6G I GWH12QC K3DNB8G I GWH12QC K3DNA6G I GWH12QC K3DNC2G I GWH12QC K3DND2G I GWH09QB K3DNA6D I GWH09QB K3DNC6G I GWH18QD K3DNA1G I GWH18QD K3DNB4G I GWH18QD K3DNB6G I GWH18QD K3...

Страница 3: ...Replacement of batteries in remote controller 15 Emergency operation 16 Maintenance Clean and Maintenance 16 Malfunction Malfunction analysis 19 Installation Notice Installation dimension diagram 23...

Страница 4: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Страница 5: ...e Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge i...

Страница 6: ...amage 2 Precautions conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill...

Страница 7: ...fore using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly...

Страница 8: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions wire which can t be used for other purposes The grounding resistance should...

Страница 9: ...emperature range Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 43 26 Maximum heating 27 24 18 The operating temperature range outdoor temperature for cooling is 15 For some model For...

Страница 10: ...rent from above graphics please refer to actual products Parts Name Indoor Unit remote control air inlet panel aux button horizontal louver air outlet NOTICE Actual product may be different from above...

Страница 11: ...r display For some model For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display G W R Power LED color...

Страница 12: ...ON TIMER OFF button SLEEP button button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Set temp O...

Страница 13: ...ill give out a sound Operation indictor is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote controller the s...

Страница 14: ...d button above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner will blo...

Страница 15: ...e indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set...

Страница 16: ...1 I FEEL button 9 Press this button to start I FEEL function and will be displayed on the remote controller After this function is set the remote controller will send the detected ambient temperature...

Страница 17: ...ncrease or decrease 1min Hold or button 2s later the time will change quickly until reaching your required time resumes displaying Cancel TIMER ON Under the condition that TIMER ON is started up press...

Страница 18: ...ed up and 8 will be shown on remote controller and the air conditioner keep the heating status Press TEMP and CLOCK buttons simultaneously again to exit 8 up or turn off 8 at 8 heating function Note U...

Страница 19: ...two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall NOTICE During o...

Страница 20: ...ff the air conditioner The operation in details are as below WARNING NOTICE Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not was...

Страница 21: ...the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly The filter should be cleaned ever...

Страница 22: ...damaged 1 Disconnect power supply 2 Clean lter and indoor unit s panel Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you...

Страница 23: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 24: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 25: ...e noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of friction caused by expa...

Страница 26: ...n off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor...

Страница 27: ...23 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall...

Страница 28: ...3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring...

Страница 29: ...it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec t...

Страница 30: ...le Wall Space to the wall above 150mm Space to the wall above 150mm 70mm Rear piping hole 2 Open a piping hole with the diameter of 55 or 70 on the selected outlet pipe position In order to drain smoo...

Страница 31: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Страница 32: ...in the indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw pane...

Страница 33: ...must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring...

Страница 34: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Страница 35: ...r damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are remo...

Страница 36: ...l refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional...

Страница 37: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 38: ...d prevent the burrs from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve insta...

Страница 39: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000078...