background image

8

 heating function

NOTE

NOTE

LIGHT

TEMP

no display

Press this button to turn off display light on indoor 

unit.  "     " icon  on  remote  controller  disappears. 

Press this button again to turn on display light.

 "       " icon is displayed.        

17

Under heat mode, press "TEMP" and "CLOCK" 

buttons simultaneously to start up or turn off 8

 

heating function. When this function is started up, 

"     " and "8

" will be shown on remote controller, 

and the air conditioner keep the heating status at 

8

. Press "TEMP" and "CLOCK" buttons simulta-

neously again to exit 8

 heating function.

Press this button, you can see indoor set tempera-

ture, indoor ambient temperature on indoor unit' s 

display. The setting on remote controller is select-

ed circularly as below:

Energy-saving function

Function introduction for 

combination buttons

Under energy-saving function, fan speed is defaulted
at auto speed and it can

'

t be adjusted.

Under energy-saving function, set temperature can

'

t

be adjusted. Press "TURBO" button and the remote
controller won

'

t send signal.

Sleep function and energy-saving function can

'

t oper-

ate at the same time. If energy-saving function has
been set under cool mode, press "SLEEP" button will
cancel energy-saving function. If sleep function has

been set under cool mode, start up the energy-saving 
function will cancel sleep function. 

The function is only available for some models.

WiFi

NOTE

NOTE

The function is only available for some models.

 

Under 8

 heating function, fan speed is defaulted at 

auto speed and it can

'

t be adjusted.

 

Under 8

 heating function, set temperature can

'

t be 

adjusted. Press "TURBO" button and the remote 
controller won

'

t send signal. 

 

Sleep function and 8

 heating function can

'

t operate 

at the same time. If 8

 heating function has been set 

under heat mode, press "SLEEP" button will cancel 8

 

heating function. If sleep function has been set under 
heat mode, start up the 8

 heating function will 

cancel sleep function. 

 

Under 

 temperature display, the remote controller 

will display 46

 heating.

Press " WiFi "  button to turn on WiFi function,   "WiFi " 

icon will be displayed on the remote controller; 

Hold " WiFi "  button for 5s to turn off WiFi function 

and " WiFi " icon will disappear.

Under off status, press "MODE" and " WiFi " buttons 

simultaneously  for  1s,  WiFi  module  will  restore 

factory settings.

Press this button to turn on or turn off the health 

and scavenging functions in operation status.

Press this button for the first time to start scaveng-

ing function; LCD displays "      ". Press the button 

for the second time to start health and scaveng-

ing functions; LCD displays "      " and "      ". Press 

this  button  for  the  third  time  to  quit  health  and 

scavenging  functions  simultaneously.  Press  the 

button for the fourth time to start health function; 

LCD  display  "      ".  Press  this  button  again  to 

repeat the operation above.

Under cooling mode, press "TEMP" and "CLOCK" 

buttons simultaneously to start up or turn off ener-

gy-saving function. When energy-saving function 

is started up, "SE" will be shown on remote con-

troller, and air conditioner will adjust the set tem-

perature automatically according to ex-factory 

setting to reach to the best energy-saving effect. 

Press "TEMP" and "CLOCK" buttons simultane-

ously again to exit energy-saving function.   

Содержание GWH07AGA-K6DNA1A/I

Страница 1: ...on and introduction of remote controller 20 Configuration of connection pipe Specialist s Manual 22 NOTE Actual product may be different from graphics please refer to actual products Thank you for cho...

Страница 2: ...9AGB K6DNA1B I GWH09AGC K6DNA1F I GWH12AGB K6DNA1A I GWH12AGB K6DNA4A I GWH12AGC K6DNA1A I GWH12AGC K6DNA1F I GWH18AGD K6DNA1A I GWH18AGD K6DNA1D I GWH18AGD K6DNA1E I GWH18AGD K6DNA4A I GWH24AGD K6DNA...

Страница 3: ...reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information u...

Страница 4: ...aware that refrigerants may not contain an odour Read specialist s manual All the work men who are engaging in the refrig eration system should bear the valid certification awarded by the authoritati...

Страница 5: ...erant If you should cut or weld the refrigerant system pipes in the process of maintaining please foll ow the steps as below c Vacuuming d e Cutting or welding Clean it with N2 gas f Carry back to the...

Страница 6: ...ir conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The groundi...

Страница 7: ...must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker...

Страница 8: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Страница 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Страница 10: ...ystem pre ssure rise or compressor rupture resulting in injury Measuring tape spanner Inner hexagon When installing or moving this unit do not charge the refrigerant which is not comply with that on t...

Страница 11: ...e requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket 5 B...

Страница 12: ...es when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 7 The pipe can be led ou...

Страница 13: ...ross hole at the back of indoor unit and then pull it out from the front side panel screw wiring cover outlet pipe drain hose All wires of indoor unit and outdoor unit should be If the length of power...

Страница 14: ...on pipe drain hose with the band drain hose band indoor power cord Put the bound pipes in the wall pipe and then Bind up the connection pipe power cord and NOTICE make them pass through the wall hole...

Страница 15: ...on 1 2 3 Clean and maintenance 2 WARNING WARNING Please contact qualified professionals for service Error Code Error code F2 E8 Troubleshooting C5 F0 F1 U8 H6 H3 E1 E5 E6 Notice for recovery 1 Clean s...

Страница 16: ...ck the batteries If the power of batter s e i o l is too w please rep lace them Under heating mode indoor temperature is reached to set temp erature Power failure Is plug loose In order to prevent blo...

Страница 17: ...turn off the air conditioner When the air conditioner is turned on it will operate under auto mode Display Temp indicator Power indicator This is the general introduction and the color of indicator i...

Страница 18: ...t Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Left right swing Up down swing Child lock Dry mode Fan mode Heat mode Temp I feel Set fan speed display ty...

Страница 19: ...multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Страница 20: ...ngle When selecting air condition er is blowing fan at xed position Horizontal louver will stop at the xed position Press or button once increase or decr ease set temperature 1 F Holding or button 2s...

Страница 21: ...display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of original factory 2 Adjust and button could...

Страница 22: ...usted Under 8 heating function set temperature can t be adjusted Press TURBO button and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If...

Страница 23: ...f the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Страница 24: ...function or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve...

Страница 25: ...m and 8m the min length of con nection pipe is 3m Max length of connection pipe is shown as below 4 1 2 The calculation method of additional refrigerant oil and refrigerant charging amount after prolo...

Страница 26: ...fferent according to the diameter please refer to the sheet below DB WB C any blemish expand the port again according to the steps above Outdoor side DB WB C Maximum GWH12AGC K6DNA1F I LC GWH09AGC K6D...

Страница 27: ...al ed or intrinsically safe Presence of fire extinguisher If any hot work is to be conducted on the refrigera tion equipment or any associated parts appropriate Ventilated area Ensure that the area is...

Страница 28: ...and being used correctly the recovery process is supervised at all times by a competent person d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that refrige...

Страница 29: ...refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not i...

Страница 30: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Tel 86 756 8522218 Fax 86 756 8669426 E mail global cn gree com Web www gree com Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 600005062912...

Отзывы: