49
Installation and Maintenance
Service Manual
Step
Procedure
Points
6. Remove electrical box
Ƶ
Disconnect the Cable
clamp
a
R e m o v e Te m p e r a t u r e
Sensor; Disconnect the
connection wires.
Twist off the earthing screw
Pull out the all the wiring
terminals
b
Pay attention to the direction
of the retainer of the
thermistor so that the
retainer will not touch the
harness (same as the
existing models.)
Terminal
board
Connecting
wires
Heat exchanger thermistor
Remove a screw on the
electrical box.
c
Heat exchanger
thermistor
Take care not to lose
the clip of themistor
Clip