4
7HFKQLFDO,QIRUPDWLRQ
Service Manual
2.2 Capacity Curve in Different Outdoor Temperature
Rated cooling condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe temperature
RIKHDWH[FKDQJHU
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
27/19
35/24
36K
0.9 to 1.1
8~11 to 11~14 75~85 to 37~43
6XSHU+LJK
+LJK
2.3 Operation Data
Cooling
Heating
5DWHGKHDWLQJFRQGLWLRQ&
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe temperature
RIKHDWH[FKDQJHU
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/-
7/6
36K
2.8 to 3.0
85 to 35
2 to 4
6XSHU+LJK
+LJK
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: .Inlet and outlet pipe temperature of condenser
33UHVVXUHDWWKHVLGHRIELJYDOYH
&RQQHFWLRQSLSHOHQJWKP
Cooling
Heating
Capacity ratio(%)
110
100
90
80
70
60
50
51 53 55
49
47
45
43
41
39
37
35
33
31
29
27
25
23
21
15
7
4
2
2
0
-7
-10
-5
0
20
40
60
80
100
120
5
10
Capacity ratio(%)
Condition Cooling
Indoor:DB27°C WB19°C
Indoor air flow: Super High
Pipe length:5m
Condition Heating
Indoor:DB20°C
Indoor air flow: Super High
Pipe length:5m
Outdoor temp.(°C)
Outdoor temp.(°C)