
70
Removal Procedure
Steps
Procedure
16. Remove condenser and capillary
Remove the
screws used for fixing the
condenser, unsolder the spot weld between
capillary and condenser (notice: before
soldering, the refrigerant should be released
completely), pull it outward and then remove the
condenser and capillary
Remove gas valve and valve support
Remove the bolts used for fixing the gas valve
and valve support, and then remove the gas
valve;
Twist off the screws used for connecting the
valve support and chassis, pull it upward and
then remove the valve support
Содержание GWC36LB-D1NNA2A/I
Страница 1: ...5 75 33 1 6 1 2 8 6HUYLFH 0DQXDO 02 11 11 5HIULJHUDQW 5...
Страница 11: ...8 65 60 40 65 60 40 3 Construction Views 3 1 Indoor Unit Constrction views 1350 326 253 253 746 351...
Страница 12: ...9 840 1018 412 3 2 Outdoor Unit Constrction views 572 950 378...
Страница 35: ...32 8 Exploded Views and Parts List 8 1 Indoor Unit Exploded Views and Parts list...
Страница 38: ...35 Exploded Views and Parts list GWC36LB D1NNA2A O 8 2 Outdoor Unit...
Страница 40: ...37 Exploded Views and Parts list GWH36LB D1NNA2A O...
Страница 49: ...46 Troubleshooting Troubleshooting for communication malfunction E6 Malfunction diagnosis flowchart...
Страница 74: ...5 75 33 1 6 1 2 8 GG LQML ZHVW 5G 4LDQVKDQ KXKDL XDQJGRQJ KLQD 3RVW FRGH 7HO IWHU VDOH 6HUYLFH HSW...