187
Installation and Maintenance
Service Manual
3.Remove grille and front panel
4.Remove axial flow blade
5.Remove right side plate
Remove connection screws between the front grille
and the front panel. Then remove the front grille.
Remove connection screws connecting the front
panel with the chassis and the motor support, and
then remove the front panel.
Remove the nut fixing the blade and then
remove the axial flow blade.
Remove connection screws connecting the right
side plate with the valve support and the electric
box. Then remove the right side plate.
Grille
Panel
Axial flow blade
Right side plate