Air Source Heat Pump Water Heater
15
is installed on the unit before ex-factory;
(2) Fig. B is the detached installation way of wired controller. Long
communication wire shall be equipped to install the wired controller on the wall. If
this kind of installation way is adopted, please contact the after-sales installation
personnel to select the communication cable with proper length;
Instructions for installing the wired controller on the wall:
①
Remove the 6 fixing screws on the top cover;
②
Remove the top cover;
③
Remove the 6 fixing screws on the front outer case subassembly;
④
Remove the front outer case subassembly;
⑤
Remove the 3 fixing screws of the gland of wired controller ;
⑥
Remove the gland and wired controller (please keep the gland of wired
controller properly for future use);
Please change the original short communication cable with long
communication wire, which is led out from the cable-crossing hole of unit;
⑦
Install decoration cover;
⑧
Tighten the fixing screw of decoration cover;
⑨
Install the front outer case subassembly;
⑩
Tighten the 6 fixing screws of front outer case subassembly;
⑪
Install the upper cover;
⑫
Tighten the fixing screw of upper cover;
⑬
Connect the wired controller with long communication cable and then install
the wired controller on the wall;