52
Maintenance
Service Manual
10.
Step
Procedure
Remove Air Flue Assy 2
Air Flue Assy 2
Screws
Unscrew 4 screws to remove the
air flue assy 2.
Unscrew 3 screws to remove the
diversion circle and cold plasma
generator assy.
Unscrew 5 screws to remove the nut
assy and gasket and centrifugal and
motor holder(upper).
Cold Plasma
Generator
Diversion Circle
Screws
Nut
Nut assy
Gasket
Gasket(M6)
Centrifugal Fan
Motor Holder(upper)
Screws
Fan Motor
Rear Grill
Cold Plasma Generator
assy
b
a
c