background image

1). To select a place near the door and window, install the exhaust duct.

2). Press "MODE" key to select "COOL" mode.

Please close the door and window, in order to obtain the better dehumidifying effect:
Press "MODE" key, select the "DRY" mode, the unit will run in the "DRY" mode, at

the same time, the upper motor is running at the low speed, it is not adjustable.

COOL mode

1). Press “MODE” key to select “HEAT” mode.

HEAT mode

(not for only 

cooling unit )

DRY mode

When the unit runs in FAN mode, it can select 3 speeds.

FAN mode

-

7

-

2). Press"    "or "    " key to set the suitable temp.16 ( 61°F ) 30 (86°F).

3). Press"    "or "    " key to set the suitable temp.16 ( 61°F ) 30 (86°F).

Operating methods

Содержание GPC07AJ-A3NNA1A

Страница 1: ...nk you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or visi...

Страница 2: ...OTE CONTROLLER 10 12 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE 16 17 ELECTRIC SCHEMATIC DIAGRAM 29 CARE AND MAINTENANCE 28 29 TROUBLESHOOTING 30 USER NOTICES 31 AFTER SALES SERVICE 32 INSTALLA...

Страница 3: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Страница 4: ...avoid noise and vibration Please put the air conditioner at smooth and flat ground for operation This air conditioner is equipped with castors Castors should slide at smooth and flat ground Prohibit...

Страница 5: ...If drainage hose is used ambient temperature can t be lower than 0 Otherwise it will cause water leakage to air conditioner Prohibit inserting any objects into the air conditioner Do not use an exten...

Страница 6: ...elegant appearance it looks like a standing Benz car It is Summary Working principle With the help of upper motor the airflow of indoor pass through the evaporator becomes the cooled wind but with the...

Страница 7: ...4 Front Rear Remote control receptor Air outlet Handle Upper air inlet grille Heat air exhaust vent Power cord Lower air inlet grille Display Board Structure...

Страница 8: ...qualified electrician USAGE NOTICE The wiring must be operated by the professional personnel by following the national regulation enough capacity in fixed circuit Don t connect earth wire to water pi...

Страница 9: ...oller operates at cooling mode after sleep mode is started up preset temperature will increase by 2 within 2 hours and then the unit will operate at this temperature all the time While if the controll...

Страница 10: ...he DRY mode the unit will run in the DRY mode at the same time the upper motor is running at the low speed it is not adjustable COOL mode 1 Press MODE key to select HEAT mode HEAT mode not for only co...

Страница 11: ...OL DRY FAN HEAT 2 Press it to increase temperature setting 4 Press it to decrease temperature setting 3 FAN Press it to set fan speed 5 Press it to set up down swing angle 6 TIMER Press it to set time...

Страница 12: ...splay is displayed by pressing the LIGHT button Press LIGHT button again to clear the display AUTO COOL DRY FAN or HEAT only for heat pump models will show 15 Left right swing icon 20 Up down swing ic...

Страница 13: ...erature is not adjustable This button is used for setting fan speed in the sequence that goes from AUTO to then back to Auto Auto Low speed Medium speed High speed 6 If the unit is turned off during s...

Страница 14: ...e n o c i e h t e d o m Y R D r o L O O C n i n o t t u b N A F X g n i s s e r P indoor fan will continue operation for 10 minutes in order to dry the indoor unit even though you have turned off the...

Страница 15: ...batteries out and reinsert them after 30 seconds If it still can t operate Sketch map for replacing batteries Press this button to go into the SLEEP operation mode Press it again to cancel this functi...

Страница 16: ...ether the set temperature is proper Whether door and window are closed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit is...

Страница 17: ...to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting After defrosting is nished it will resume operation No fan blowed out from air conditioner Ther...

Страница 18: ...to maintain the unit F0 F2 F1 H8 H3 E8 F4 1 Refrigerant is leaking 2 System is blocked 1 Re energize the unit after turning off and pulling out the plug for 30min 2 If there s still malfunction please...

Страница 19: ...re by the manufacturer correct under 51 inchs about 24 inchs User can adjust the installation method of the discharge pipe basing on the requirement while the similar installation methods as below whi...

Страница 20: ...ith shortest length When installing heat discharge pipe should be as flat as possible Don t prolong the pipe or connect it with other heat discharge pipe PARTS INCLUDED Front plastic pipe end Flexible...

Страница 21: ...window stool If the inner width of the window is be tween 22 559mm and 24 609mm inclusive The window panel cannot be installed in windows less than 22 559mm wide as you will be unable to shut the exha...

Страница 22: ...dow sash and place the window panel on the window stool 3 Slide the adjustment and extension panels to fi t the window frame width 4 Secure the window panel to the window stool with 4 screws 4 Cut the...

Страница 23: ...indow panel into the window frame If the inner height of the window is between 22 559mm and 24 609mm inclusive The window panel cannot be installed in windows less than 22 559mm high as you will be un...

Страница 24: ...adjustment panel 2 Open the window sash and place the window panel on the window frame 3 Slide the adjustment and extension panels to fit the window frame height 4 Secure the window panel to the windo...

Страница 25: ...nsion panel and attach foam seal B to the adjustment panel 5 Close the window sash securely against the Window panel 6 Cut the foam seal to an appropriate length and seal the opening between the side...

Страница 26: ...t 1 rotate the hose anticlockwise into the joint 1 Connect rear plate 1 and rear plate 2 fix the adjustable plate at the sliding groove of rear plate 1 put the adjustable plate into the rear plate to...

Страница 27: ...r s requirement rear plate 1 rear plate 2 screw adjustable plate can slide in the sliding groove of rear plate 1 and rear plate 2 clasp of protective grille screw Install protective grille aim the pro...

Страница 28: ...outlet groove of back plate joint 1 baffle air outlet Install baffle air outlet when the unit is not to be used press the clasp of protective grille to make it separate from the rear plate 1 and then...

Страница 29: ...s the clasp at the lower side of back plate assemble the second wire hook upwards into the groove of lower clasp remote controller box groove wire hook clasp Install remote controller box the opening...

Страница 30: ...d to Drainage way as follows the chassis 2 When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge water Move the unit to a suitable place...

Страница 31: ...e There are wheels at the bottom of the unit according to the demand it can be moved in the Move unit Air inlet grille Before maintenance please pull out the power plug and cut off power supply to avo...

Страница 32: ...WH BU BU N3 S COMP YEGN C YE C1 K201 L COMP N1 WATER1 DISP2 RD RD BU SA COM WH HIGH WP RD DISP2 ROOM TEMP DISP1 AP2 M3 SENSOR G G RT2 RT1 BK NC DISP1 G C2 RD FAN BN M1 YEGN FAN BOARD DISPLAY REC RECE...

Страница 33: ...tion after defrosting 1 Unit is running in defrosting operation it will resume running in original operation after defrosting 1 Pour out water in the tank 2 If the malfunction still exists please info...

Страница 34: ...locked by obstruction or it will cause malfunction Do not insert hands or stick into the air inlet or outlet especially pay more attention to young children or it can cause the accident easily Static...

Страница 35: ...posed of at least free of charge to the user b When buying a new product the retailer will take back the old product at least free of charge DISPOSAL Do not dispose this product as unsorted municipal...

Страница 36: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com 600005060539...