SAFETY WARNING

•  This appliance can be used by children aged from 8 years and

above and people with reduced physical ,sensory or mental

capabilities or lack of experience and knowledge if they have

been given supervision or instruction concerning use of the

appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance. Cleaning and user

maintenance shall not be made by children without supervision.

•  Before operation, please confirm whether power specification

complies with that on nameplate.

•  Before cleaning or maintaining the air conditioner, please turn off

air conditioner and pull out the power plug.

•  Make sure the power cord hasn't been pressed by hard objects.

•  Do not pull or drag the power cord to pull out the power plug or

move the air conditioner.

•  Do not insert or pull out the power plug with wet hands.

•  Please use the grounded power. Make sure the gounding is reliable.

•  If the supply cord is damaged, it must be replaced by the

manufacturer or its service agent or a similarly qualified person

in order to avoid a hazard.

•  If the power cord is damaged, it must be replaced by

manufacturer or professional person.

•  If abnormal condition occurs (e.g. burned smell), please

disconnect power at once and then contact local dealer.

•  When nobody is taking care of the unit, please turn it off and

remove the power plug or disconnect power.

•  Do not splash or pour water on air conditioner. Otherwise, it may

cause short circuit or damage to air conditioner.

•  If drainage hose is used, ambient temperature can't be lower than

0°C .Otherwise, it will cause water leakage to air conditioner.

•  Prohibit operating heating equipment around the air conditioner.

•  Keep far away from fire source, inflammable and explosive objects.

•  Children and disabled people are not allowed to use the

portable room air conditioner without supervision.

•  Keep children from playing or climbing on the air conditioner.

•  Do not put or hang dripping objects above the air conditioner.

•  Do not repair or disassemble the air conditioner by yourself.

•  Prohibit inserting any objects into the air conditioner.

•  Do not use an extension cord

Содержание GPC05AK-A3NNA2B

Страница 1: ...oeil Quebec Canada Made in China OWNER S MANUAL PORTABLE AIR CONDITIONER Thank you for choosing our product Please read this owner s manual carefully before operation and retain it for future referenc...

Страница 2: ...ION BEFORE INSTALLATION 18 INSTALLING WIRE HOOK 19 REMOVING COLLECTED WATER 20 INSTALLATION IN A DOUBLE HUNG SASH WINDOW 23 INSTALLATION IN A SLIDING SASH WINDOW 26 INSTALLATION OF HEAT DISCHARGE PIPE...

Страница 3: ...not operate the air conditioner at humid environment Please keep air inlet and air outlet clean no obstacles During operation close doors and windows to improve cooling effect Please put the air condi...

Страница 4: ...ged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard If the power cord is damaged it must be replaced by manufacturer or professi...

Страница 5: ...l product for the appearance Remote controller 1 Controller panel 2 Swing louver 3 Guide louver 4 Castor 5 Plug of power cord 7 Gastor 8 Air inlet 9 Joint A 10 Heat discharge pipe 11 Joint B C 6 1 11...

Страница 6: ...6 Copyright GREE Canada 2021 OPERATION INTRODUCTION FOR CONTROL PANEL NAME OF CONTROL PANEL OPERATION OF CONTROL PANEL...

Страница 7: ...imer button to enter into timer setting mode Under this mode press or button to adjust the timer setting Timer setting will increase or decrease 0 5 hour up to a maximum of 10 hours After timer settin...

Страница 8: ...8 Copyright GREE Canada 2021 BUTTONS ON REMOTE CONTROLLER INTRODUCTION FOR ICONS ON DISPLAY SCREEN...

Страница 9: ...9 Copyright GREE Canada 2021 INTRODUCTION FOR BUTTONS ON REMOTE CONTROLLER...

Страница 10: ...10 Copyright GREE Canada 2021...

Страница 11: ...ate you may hold and buttons simultaneously for 3 seconds to set the lamp on or off and send the code After being energized the lamp is defaulted on About Light function REPLACEMENT OF BATTERIES IN RE...

Страница 12: ...s much dust in the operation environment you can increase clean frequency Do not dry the filter with fire or hair drier Otherwise it may be deformed or catch fire Clean outer case If there s dust on...

Страница 13: ...ason 1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage wayn for detail...

Страница 14: ...unit Please contact after sales maintenance person Poor cooling heating Is the power too low Wait after voltage is resumed Whether the air filter is too dirty Clean the air filter Whether the set tem...

Страница 15: ...hether the required temperature exceeds the temperature setting range Temperature setting range 61 F 17 C 86 F 30 C The device gives off an odor There s off flavor source in the room such as furniture...

Страница 16: ...and then energize it for operation 3 If the malfunction still occur please contact our after sales service center 1 Re energize the unit after turning off and pulling out the plug for 30min 2 If ther...

Страница 17: ...ance shall not be installed in the laundry Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supp...

Страница 18: ...18 Copyright GREE Canada 2021 PREPARATION BEFORE INSTALLATION...

Страница 19: ...HOOK Assemble the wire hook at the back of the unit with screws the direction of wire hook is as shown in following fig Direction of wire hook is upward Direction of wire hook is downward Wire hook S...

Страница 20: ...nto the other side of drainage pipe fix it with pipe hoop and then fix it in the drainage pipe clip Drainage port Drainage pipe clip Drainage pipe Pipe hoop Drainage port Screw Rubber plug Pipe hoop D...

Страница 21: ...ge the water frequently 2 When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge water Move the unit to a suitable place for discharging...

Страница 22: ...or included in the package to the spout by turning clockwise ATTENTION When using continuous drainage option from the middle hole place portable on a level surface and make sure garden hose is clear o...

Страница 23: ...e Rear connector upper Clap Rear connector lower Window frame Joint B C Inner side s w e r c S s w e r c S Protective grille Cut 1 Install rear clip Aim the rear clip upper at the rear clip lower fix...

Страница 24: ...l to the window stool 7 1 If the inner width of the window is less than 20 5 520mm The window panel cannot be installed in windows less than 20 5 520mm wide 1 Remove the adjustment panel from the wind...

Страница 25: ...25 Copyright GREE Canada 2021 950 37 4 950mm 37 4 56 7 37 4 56 7 1440mm 37 4...

Страница 26: ...per part of inner window sash and outer window sash 11 Fix the inner window with window bracket and screw so that it can not slide vertically dow sash securely against the Window panel 1 Install rear...

Страница 27: ...and bolt 5 Fix the support on the outer side of window frame with 2 nuts spring washer washer and bolt NOTE protective grille support rain shield nut bolt spring washer and washer are optional access...

Страница 28: ...28 Copyright GREE Canada 2021 37 4 950...

Страница 29: ...29 Copyright GREE Canada 2021 37 4 56 7 950 1440 37 4 56 7...

Страница 30: ...per length and seal the gap between left side of inner window sash and outer window sash 11 Fix the inner window with window bracket and screw so that it can not slide horizontally Outer window Window...

Страница 31: ...A Clasp Groove The side with TOP is upwards Heat discharge pipe Clockwise Heat discharge pipe 2 Install another side of heat discharge pipe clockwise into protective grille sub assy 3 Insert joint A o...

Страница 32: ...at discharge pipe should be as short as possible and flat without curve to ensure smooth heat discharge The length of the heat discharge pipe is less than 1m It is recommended to use it with shortest...

Страница 33: ...cm above floor Wrong installation is shown in following figure If the pipe is bent too much it would easily cause malfunction 1 Remove joint A Press the clasp and lift joint A upwards to remove it Cla...

Страница 34: ...ply and then press ON OFF button on remote controller to start the unit Press mode button to select auto cooling drying fan or heating function and then check if the unit operates normally If ambient...

Страница 35: ...MP TUBE REC RECEIVER RT2 RT1 BOARD DISPLAY BOARD ROOM POWER L N BU N3 S COMP YEGN C YE CAP K201 AC L COMP AP1 N1 WATER DISP2 RD FAN RD BU SA COM WH HIGH WP RD DISP2 ROOM TEMP DISP1 AP2 M1 BN MOTOR FAN...

Страница 36: ...uring the warranty period if this Air Conditioner fails under normal use GREE will at its option either repair the unit or replace it free of charge within a reasonable period of time after the Air Co...