background image

17

© Copyright, GREE Canada, 2021

 

© Copyright, GREE Canada, 2021

WARNING

WARNING

• Observe all governing codes and ordinances.

• Do not use damaged or non-standard power cord.

• Be caution during installation and maintenance. Prohibit incorrect operation

to prevent electric shock, casualty and other accidents.

Basic requirement

Installing the unit in the following places may cause malfunction. If it is unavoi-

dable, please consult the local dealer:

1. The place with strong heat sources, vapors, flammable or explosive gas, or 

volatile objects spread in the air.

2. The place with high-frequency devices (such as welding machine, medical 

equipment).

3. The place near coast area.

4. The place with oil or fumes in the air.

5. The place with sulfureted gas.

6. Other places with special circumstances.

Requirement of air conditioner

1. Air inlet should be far away from obstacles and do not put any objects near air 

outlet. Otherwise, it will affect the radiation of heat discharge pipe.

2. Select a location where the noise and outflow air emitted by the outdoor unit will

not affect neighborhood.

3. Please try your best to keep far away from fluorescent lamp.

4. The appliance shall not be installed in the laundry.

Safety precaution

1. Must follow the electric safety regulations when installing the unit.

2. According to the local safety regulations, use qualified power supply circuit.

3. For appliances with type Y attachment, the instructions shall contain the 

substance of the following.lf the supply cord is damaged,it must be replaced by

the manufacturer, its service agent or similarly qualified persons in order to 

avoid a hazard.

4.  Properly connect the live wire, neutral wire and grounding wire of power socket.

5.  Be sure to cut off the power supply before proceeding any work related to 

electricity and safety.

6.  Do not put through the power before finishing installation.

7.  The air conditioner is first class electric appliance. It must be properly grounding

with specialized grounding device by a professional. Please make sure it is 

always grounded effectively, otherwise it may cause electric shock.

8.  The yellow-green wire or green wire in air conditioner is grounding wire, which 

can't be used for other purposes.

9.  The grounding resistance should comply with national electric safety 

regulations.

10. The appliance shall be installed in accordance with national wiring regulations.

Selection of installation location

Requirements for electric connection

INSTALLATION PRECAUTION

Содержание GPC05AK-A3NNA2B

Страница 1: ...oeil Quebec Canada Made in China OWNER S MANUAL PORTABLE AIR CONDITIONER Thank you for choosing our product Please read this owner s manual carefully before operation and retain it for future referenc...

Страница 2: ...ION BEFORE INSTALLATION 18 INSTALLING WIRE HOOK 19 REMOVING COLLECTED WATER 20 INSTALLATION IN A DOUBLE HUNG SASH WINDOW 23 INSTALLATION IN A SLIDING SASH WINDOW 26 INSTALLATION OF HEAT DISCHARGE PIPE...

Страница 3: ...not operate the air conditioner at humid environment Please keep air inlet and air outlet clean no obstacles During operation close doors and windows to improve cooling effect Please put the air condi...

Страница 4: ...ged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard If the power cord is damaged it must be replaced by manufacturer or professi...

Страница 5: ...l product for the appearance Remote controller 1 Controller panel 2 Swing louver 3 Guide louver 4 Castor 5 Plug of power cord 7 Gastor 8 Air inlet 9 Joint A 10 Heat discharge pipe 11 Joint B C 6 1 11...

Страница 6: ...6 Copyright GREE Canada 2021 OPERATION INTRODUCTION FOR CONTROL PANEL NAME OF CONTROL PANEL OPERATION OF CONTROL PANEL...

Страница 7: ...imer button to enter into timer setting mode Under this mode press or button to adjust the timer setting Timer setting will increase or decrease 0 5 hour up to a maximum of 10 hours After timer settin...

Страница 8: ...8 Copyright GREE Canada 2021 BUTTONS ON REMOTE CONTROLLER INTRODUCTION FOR ICONS ON DISPLAY SCREEN...

Страница 9: ...9 Copyright GREE Canada 2021 INTRODUCTION FOR BUTTONS ON REMOTE CONTROLLER...

Страница 10: ...10 Copyright GREE Canada 2021...

Страница 11: ...ate you may hold and buttons simultaneously for 3 seconds to set the lamp on or off and send the code After being energized the lamp is defaulted on About Light function REPLACEMENT OF BATTERIES IN RE...

Страница 12: ...s much dust in the operation environment you can increase clean frequency Do not dry the filter with fire or hair drier Otherwise it may be deformed or catch fire Clean outer case If there s dust on...

Страница 13: ...ason 1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage wayn for detail...

Страница 14: ...unit Please contact after sales maintenance person Poor cooling heating Is the power too low Wait after voltage is resumed Whether the air filter is too dirty Clean the air filter Whether the set tem...

Страница 15: ...hether the required temperature exceeds the temperature setting range Temperature setting range 61 F 17 C 86 F 30 C The device gives off an odor There s off flavor source in the room such as furniture...

Страница 16: ...and then energize it for operation 3 If the malfunction still occur please contact our after sales service center 1 Re energize the unit after turning off and pulling out the plug for 30min 2 If ther...

Страница 17: ...ance shall not be installed in the laundry Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supp...

Страница 18: ...18 Copyright GREE Canada 2021 PREPARATION BEFORE INSTALLATION...

Страница 19: ...HOOK Assemble the wire hook at the back of the unit with screws the direction of wire hook is as shown in following fig Direction of wire hook is upward Direction of wire hook is downward Wire hook S...

Страница 20: ...nto the other side of drainage pipe fix it with pipe hoop and then fix it in the drainage pipe clip Drainage port Drainage pipe clip Drainage pipe Pipe hoop Drainage port Screw Rubber plug Pipe hoop D...

Страница 21: ...ge the water frequently 2 When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge water Move the unit to a suitable place for discharging...

Страница 22: ...or included in the package to the spout by turning clockwise ATTENTION When using continuous drainage option from the middle hole place portable on a level surface and make sure garden hose is clear o...

Страница 23: ...e Rear connector upper Clap Rear connector lower Window frame Joint B C Inner side s w e r c S s w e r c S Protective grille Cut 1 Install rear clip Aim the rear clip upper at the rear clip lower fix...

Страница 24: ...l to the window stool 7 1 If the inner width of the window is less than 20 5 520mm The window panel cannot be installed in windows less than 20 5 520mm wide 1 Remove the adjustment panel from the wind...

Страница 25: ...25 Copyright GREE Canada 2021 950 37 4 950mm 37 4 56 7 37 4 56 7 1440mm 37 4...

Страница 26: ...per part of inner window sash and outer window sash 11 Fix the inner window with window bracket and screw so that it can not slide vertically dow sash securely against the Window panel 1 Install rear...

Страница 27: ...and bolt 5 Fix the support on the outer side of window frame with 2 nuts spring washer washer and bolt NOTE protective grille support rain shield nut bolt spring washer and washer are optional access...

Страница 28: ...28 Copyright GREE Canada 2021 37 4 950...

Страница 29: ...29 Copyright GREE Canada 2021 37 4 56 7 950 1440 37 4 56 7...

Страница 30: ...per length and seal the gap between left side of inner window sash and outer window sash 11 Fix the inner window with window bracket and screw so that it can not slide horizontally Outer window Window...

Страница 31: ...A Clasp Groove The side with TOP is upwards Heat discharge pipe Clockwise Heat discharge pipe 2 Install another side of heat discharge pipe clockwise into protective grille sub assy 3 Insert joint A o...

Страница 32: ...at discharge pipe should be as short as possible and flat without curve to ensure smooth heat discharge The length of the heat discharge pipe is less than 1m It is recommended to use it with shortest...

Страница 33: ...cm above floor Wrong installation is shown in following figure If the pipe is bent too much it would easily cause malfunction 1 Remove joint A Press the clasp and lift joint A upwards to remove it Cla...

Страница 34: ...ply and then press ON OFF button on remote controller to start the unit Press mode button to select auto cooling drying fan or heating function and then check if the unit operates normally If ambient...

Страница 35: ...MP TUBE REC RECEIVER RT2 RT1 BOARD DISPLAY BOARD ROOM POWER L N BU N3 S COMP YEGN C YE CAP K201 AC L COMP AP1 N1 WATER DISP2 RD FAN RD BU SA COM WH HIGH WP RD DISP2 ROOM TEMP DISP1 AP2 M1 BN MOTOR FAN...

Страница 36: ...uring the warranty period if this Air Conditioner fails under normal use GREE will at its option either repair the unit or replace it free of charge within a reasonable period of time after the Air Co...

Отзывы: