1.2 Installation of Ceiling Type
1.2.1 Before Installation
When the unit arrives, please check if any damage due to transport is existent. If any hurt is found on the
surface or inside, please declare to the transport company or the manufacturer in writing.
When the unit arrives, please check if any damage due to transport is existent. If any hurt is found on the
surface or inside, please declare to the transport company or the manufacturer in writing.
Correct handling route and method shall be decided to prevent damage to the unit. For protecting the
unit and ensuring its safety, carrying the unit with its package is recommended. If such carrying method is
GLI¿FXOWXQGHUSDUWLFXODUFRQGLWLRQVWKHFDQWRQVKDOOQRWEHUHPRYHGWRDYRLGORRVHQHVVRUIDOOLQJGXULQJ
handling.
Confirm the foundation is secure. When the unit is installed on the metal part of a building, electrical
insulation must be in compliance with relevant standards.
&RQ¿UPWKHLQVWDOODWLRQSRVLWLRQLVDZD\IURPVWRUDJH]RQHRILQÀDPPDEOHDQGH[SORVLYHVXEVWDQFHVRU
RWKHUZLVHOHDNDJHRILQÀDPPDEOHDQGH[SORVLYHVXEVWDQFHVPD\OHDGWRH[SORVLRQRUD¿UH
1.2.2 Installation Site
Such a place where cool air can be distributed throughout the room.
Such a place where condensation water is easily drained out.
Such a place that can handle the weight of indoor unit.
Such a place which has easy access for maintenance.
Such a place where is permitting easy connection with the outdoor unit.
Such a place where is 1m or more away from other electric appliances such as television, audio device,
etc.
$YRLGDORFDWLRQZKHUHWKHUHLVKHDWVRXUFHKLJKKXPLGLW\RULQÀDPPDEOHJDV
Do not use the unit in the immediate surroundings of a laundry, a bath, a shower or a swimming pool.
Be sure that the installation conforms to the installation dimension diagram.
7KHVSDFHDURXQGWKHXQLWLVDGHTXDWHIRUYHQWLODWLRQ
1.2.3 Caution for Installation
Adjust the distance from the unit to the ceiling slab beforehand (Refer to Figure 1-2-1).
Fix the hanger bracket to the suspension bolt (Refer to Figure 1-2-2).
Make sure that extended suspension bolt from the ceiling stays inside the arrowed position. Readjust the hanger
bracket when it is outside the arrowed position. (Refer to Figure 1-2-3)
Suspension bolt stays inside the cap of indoor unit .Never remove the cap. Lift the unit and slide forward unit the dent.
(Refer to Figure 1-2-4)
Screw tightly both hanger bracket setting bolts (M8) (Refer to Figure 1-2-2)
6FUHZWLJKWO\ERWKKDQJHUEUDFNHW¿[LQJEROWV0WRSUHYHQWWKHPRYHPHQWRIWKHLQGRRUXQLW5HIHUWR)LJXUH
Adjust the height by turning the nut with a spanner. Insert the spanner from the hanger bracket opening. (Refer to
Figure 1-2-5)
PPRUOHVV
Suspension bolt
Ceiling
Hanger bracket
Hanger bracket
setting bolt(M8)
Hanger bracket
foxing bolt(M6)
Hanger bracket Figure 1-2-1 Figure 1-2-2
Содержание GKH12K3BI
Страница 1: ...U MATCH AIR CONDITIONERS SERVICE MANUAL T1 R410A 50Hz...
Страница 4: ...1 U MATCH Air Conditioners Service Manual PRODUCT QSPEVDU...
Страница 31: ...28 U MATCH Air Conditioners Service Manual CONTROL DPOUSPM...
Страница 32: ...29 U MATCH Air Conditioners Service Manual DPOUSPM CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation...
Страница 33: ...30 U MATCH Air Conditioners Service Manual DPOUSPM 1 2 Heating Operation...
Страница 50: ...47 U MATCH Air Conditioners Service Manual INSTALLATION...
Страница 86: ...83 U MATCH Air Conditioners Service Manual MAINTENANCE...
Страница 93: ...90 U MATCH Air Conditioners Service Manual Malfunction display E6 Communications Failure...
Страница 111: ...108 U MATCH Air Conditioners Service Manual Model GTH30K3B1I Model GTH60K3B2I...
Страница 151: ...148 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Страница 156: ...153 U MATCH Air Conditioners Service Manual 5 Model GUHN42NM3AO GUHN48NM3A1O Exploded Views...
Страница 158: ...155 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3AO Exploded Views...
Страница 160: ...157 U MATCH Air Conditioners Service Manual 7 Model GUHN60NM3A2O Exploded Views...
Страница 165: ...162 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Страница 168: ...165 U MATCH Air Conditioners Service Manual 4 Model GUHN36NK3AO GUHN36NM3AO Exploded Views...
Страница 170: ...167 U MATCH Air Conditioners Service Manual 5 Model GUHN42NM3AO GUHN48NM3A1O GUHN60NM3AO Exploded Views...
Страница 173: ...170 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3A2O Exploded Views...
Страница 175: ...172 U MATCH Air Conditioners Service Manual 7 Model GUCN42NM3AO Exploded Views...
Страница 177: ...174 U MATCH Air Conditioners Service Manual 8 Model GUCN48NM3AO Exploded Views...
Страница 184: ...181 U MATCH Air Conditioners Service Manual 2 2 Cassette Type 1 Model GKH12K3BI GKH18K3BI Exploded Views...
Страница 186: ...183 U MATCH Air Conditioners Service Manual 2 Model GKH24K3BI GKH36K3BI GKH42K3BI Exploded Views...
Страница 189: ...186 U MATCH Air Conditioners Service Manual 3 Model GKH30K3B1I Exploded Views...
Страница 191: ...188 U MATCH Air Conditioners Service Manual 4 Model GKH42K3B1I GKH48K3B3I Exploded Views...
Страница 193: ...190 U MATCH Air Conditioners Service Manual 5 Model GKH60K3B2I Exploded Views...
Страница 209: ...JF00300193...