7
© Copyright, GREE Canada, 2021
© Copyright, GREE Canada, 2021
RECOMMENDED GROUND METHOD
For your personal safety, this air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong plug. To minimize possible
shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded
in accordance with all local codes and ordinances. If a mating outlet is not available, it is
the customer’s responsibility to have a properly grounded 3 prong outlet installed by a
qualified electrical installer.
POWER SUPPLY CORD
NOTE:
Your unit’s device may differ from the one shown.
It is the customer’s responsibility:
1) To contact a qualified electrical installer.
2) To assure that the electrical installation is adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.
The place near coast area.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
This room air conditioner is equipped
with a power supply cord required by
UL. This power supply cord contains
state-of-the-art electronics that sense
leakage current. If the cord is crushed,
the electronics detect leakage current
and power will be disconnected in a
fraction of a second.
A
B
To test your power supply cord:
1) Plug power supply cord into a grounded 3 prong outlet.
2) Press RESET (on some devices, a green light will turn on).
3) Press TEST (listen for click; Reset button will trip, and on some devices, a green light will turn off).
4) Press and release RESET (listen for click; Reset button will latch, and on some devices, a green light
will turn on). The power supply cord is ready for operation.
Note:
1) The Reset button must be pushed in for proper operation.
2) The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to
reset.
3) Do not use the power supply cord as an off/on switch. The power supply cord is designed as a
protective device.
4) A damaged power supply cord must be replaced with a new power supply cord obtained from the
product manufacturer and must not be repaired.
5) The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids
all warranty and performance claims.
A. Reset button
B. Test button