background image

Emergency operation

If remote controller is lost or damaged, please use auxiliary button to turn

on or turn off the air conditioner. The operation in details are as below:

air conditioner. When the air conditioner is turned on, it will operate under

auto mode.

Clean and maintenance

 Turn off the air conditioner and disconnect the power before cleaning the air 

   conditioner to avoid electric shock.

■ Do not wash the air conditioner with water to avoid electric shock.

■ Do not use volatile liquid to clean the air conditione

r.

Clean surface of indoor unit

When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth 

or wet cloth to wipe it.

NOTICE:

● Do not remove the panel when cleaning it.

WARNING

1

8

panel

aux. button

WARNING:

Use insulated object to press the auto button

Содержание GISF909A

Страница 1: ...f you have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper operation please read and keep this manual...

Страница 2: ......

Страница 3: ...Leakage detection 37 Check after installation 38 Test and operation Test operation 38 Attachment 39 Pipe expanding method 41 This appliance is not intended for use by persons including children with r...

Страница 4: ......

Страница 5: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Страница 6: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 7: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 8: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Страница 9: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Страница 10: ...unavoidable please add the fence for safety purpose Select a location which is out of reach for children and reachable after finishing installation For the air conditioner with plug the plug should be...

Страница 11: ...please refer to actual products Parts Name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet remote control Actual product may be different from above graphics please re...

Страница 12: ...el For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display For some model heating indicator temp indica...

Страница 13: ...utton 5 button Send signal Turbo mode 8 heating function Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Light Temp display type Set temp Outdoor a...

Страница 14: ...ess button to adjust fan blowing angle Cooling only unit won t receive heating mode signal If setting heat mode with remote controller press ON OFF button can t start up the unit Introduction for butt...

Страница 15: ...ng button after setting is nished temperature indica tor on indoor unit will change accordingly Temperature can t be adjusted under This button is used for setting Fan Speed in the sequence that goes...

Страница 16: ...e Hold button above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner wil...

Страница 17: ...iginal factory 2 Adjust and button could change the corresponding setting temperature after adjusted press Turbo button for confirmation 3 At this time 1hour will be automatically increased at the tim...

Страница 18: ...to avoid detecting inaccurate ambient temperature When I FEEL function is turned on the remote controller should be put within the area where indoor unit can receive the signal sent by the remote cont...

Страница 19: ...function is selected The Quiet function is only available for some models Under cooling mode indoor fan operates at notch 4 speed 10 minutes later or when indoor ambient temperature 28 indoor fan wil...

Страница 20: ...ecting with remote controller temperature indicator on indoor unit displays indoor ambient temperature When selecting with remote controller temperature indicator on indoor unit displays outdoor ambie...

Страница 21: ...press sleep button will cancel 8 heating function If sleep function has been set under cooling mode start up the 8 heating function will cancel sleep function Under temperature display the remote con...

Страница 22: ...eries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operation point the remote contr...

Страница 23: ...air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to cl...

Страница 24: ...pen panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean f...

Страница 25: ...pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recycl...

Страница 26: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 27: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 28: ...unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or...

Страница 29: ...ng the unit If not please When below phenomenon occurs please turn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch tr...

Страница 30: ...east 50cm At least 30cm At least 300cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction...

Страница 31: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Страница 32: ...lation Don t use unqualified power cord Basic requirement Outdoor unit Indoor unit Installing the unit in the following pla ces maycause malfunction If it is un avoidable please consult the local deal...

Страница 33: ...rdance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yel...

Страница 34: ...e to the wall above 150mm 55mm Rear piping hole QB 29 Installation of indoor unit Step one choosing installation location Step two install wall mounting frame rm it with the client 1 Hang the wall mou...

Страница 35: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Страница 36: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Страница 37: ...in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm power connection wire cable cross hole 2 Make the power connection wire go through the c...

Страница 38: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Страница 39: ...For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10...

Страница 40: ...t with hand 4 Tighten the union nut with torque wrench by referring to the sheet below gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12...

Страница 41: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...

Страница 42: ...erant charging vent 2 Connect the charging hose of piezometer to the refri gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump 3 Open the piezometer com plete...

Страница 43: ...r damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are remo...

Страница 44: ...he additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe...

Страница 45: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 46: ...n suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the po...

Страница 47: ......

Страница 48: ...66129930512...

Отзывы: