88
Installation and Maintenance
Service Manual
Tear off the sticking stripe and then remove the
soundproof sponge.
Remove the 2 screws connecting the isolation plate
and condenser side plate; remove the 3 screws
connecting the isolation plate and chassis, and then
remove the isolation plate.
Unsolder the welding joints connecting the 4-way
valve assy with capillary sub-assy, compressor and
condenser; remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.
Steps
Procedure
8. Remove
4-way valve assy
7. Remove isolation plate
6. Remove the soundproof sponge
soundproof sponge
isolation plate
4-way valve assy
Содержание GH18QD-D3DNA6E(LCLH)
Страница 1: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Change for Life Service Manual ...
Страница 13: ...10 Technical Information Service Manual 3 2 Outdoor Unit Unit inch 35 13 3 8 27 9 16 15 5 8 38 14 5 16 22 ...
Страница 42: ...39 Installation and Maintenance Service Manual 9 2 Error Code List ...