Operating guide
OPERATION INSTRUCTIONS
Working principle and special functions for cooling
Working principle and special functions for heating
Defrosting:
*
When outdoor temperature is low but high humidity, after a long while running, frost will
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 8-10mins.
*
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may
emit vapor, This is due to the defrosting, it isn't malfunction.
*
After defrosting finished,the heating will recover automatically.
The climate type of this unit is according to the nameplate.
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that
indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
If the unit is running in COOL mode and in low temperature, there will be frost formed on
the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the
indoor unit microcomputer will stop compressor running and protect the unit.
℃
Principle:
*
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease.
*
If outdoor temperature becomes very low, please operate with other heating equipments.
Anti-cool wind function:
In Heat mode, the following three kinds of status, if indoor heat exchanger hasn't achieve
certain temperature that indoor fan motor will not start, in this way to prevent blowing cool
wind (within 3mins):
1. Heat operation just startedup. 2. After Auto defrosting operation is finished.
3. Heating under low temperature.
Principle:
Anti-freezing function:
1
6
Содержание GEH09AA-K6DNA1F/I
Страница 2: ...GEH09AA K6DNA1F I GEH12AA K6DNA1A I GEH18AA K6DNA1F I...
Страница 39: ......
Страница 40: ...66129931224...
Страница 42: ......
Страница 43: ...GEH09AA K6DNA1F O GEH12AA K6DNA1A O GEH18AA K6DNA1F O...
Страница 67: ......
Страница 68: ...66129931225...
Страница 70: ...GEH09AA K6DNA1F I GEH12AA K6DNA1A I GEH18AA K6DNA1F I...
Страница 108: ...GEH09AA K6DNA1F O GEH12AA K6DNA1A O GEH18AA K6DNA1F O...
Страница 134: ...GEH09AA K6DNA1F I GEH12AA K6DNA1A I GEH18AA K6DNA1F I...
Страница 170: ......
Страница 171: ......
Страница 174: ...GEH09AA K6DNA1F O GEH12AA K6DNA1A O GEH18AA K6DNA1F O...