SAFETY INFORMATION

 

The power cord with this air conditioner contains a current detection device designed to 

reduce the risk of fire. Please refer to the section “operation of current device” for details. In the 
event that the power cord is damaged, it cannot be repaired. It must be replaced with a power 
cord from the product manufacturer. 

 

NOTE:

 

If you turn off the air conditioner, wait at least three MINUTES before turning it back on.  This 

prevents the unit from blowing a fuse or tripping a circuit breaker. 

Operation of Current Device

The power cord contains a current device that senses damage to the power cord. To test your power cord, do the 

following:
1.  Plug in the Air Conditioner.

2.  The power cord has TWO buttons on the 3-Prong Grounding Plug. Press the TEST button. You will notice a 

click as the RESET button pops out. 

3.  Press the RESET button, and you will hear a click as the button engages. 

4.  The power cord is now supplying electricity to the unit. 

(On some products this is also indicated by a light on 

the 

3-Prong Grounding Plug

)

.

NOTE:

•  Do not use the power cord to turn the unit on or off. 
•  Always make sure the RESET button is pushed in for correct operation. 
•   The power cord must be replaced if it fails to reset when either the TEST button is pushed,  

or it cannot be reset. Please contact Customer Service. 

•   If the power cord is damaged, then it cannot be repaired. It MUST be replaced with a new power cord.  

Please contact Customer Service.

Power Cord with 3-Prong 

Grounding Plug and Current 

Detection Device.

   The power cord is equipped with a 3-Prong Grounding Plug which 

can only be used with a standard 3-prong wall outlet to minimize the 

possibility of electric shock hazard. Where a 2-prong outlet is 

encountered, it is your responsibility to have it replaced with a properly 

grounded 3-prong wall outlet.  

•   Do not use a power cord that shows damage or cracks along the 

length or at the connector. A damaged power cord should be replaced 

with a new cord obtained from the manufacturer. Please contact 

Customer Service for replacement options.  

•   Do not modify power cord length or share an outlet with another 

appliance. This may cause electric shock or fire.  

•   Always use a dedicated power circuit. The voltage on the outlet 

should match the voltage rating on the rating plate.  

•   Do not use the outlet if it is loose or damaged. It may cause electric 

shock.  

•  Never use an extension cord, surge protector, or multi-outlet adapter 

with this unit.

SAFETY INFORMATION

Electrical Information

Do not under any 

circumstances cut, 

remove, or bypass the 

grounding prong

Содержание G17-6CWAC

Страница 1: ...ial numbers below for your records Model Serial Date Purchased Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please visit www greeproducts com Phone 1 866 658 0466 Email customerservice greeproducts com ...

Страница 2: ...ALLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 14 CLEANING MAINTENANCE 15 16 BEFORE YOU CALL 17 19 WARRANTY 20 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please refer to the actual product for the appearance ...

Страница 3: ... not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not place obstacles around air inlets or inside of air outlet Switch off the unit and unplug the unit before cleaning To prevent injury when the air filter needs to be removed do not touch the metal parts...

Страница 4: ...wer cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUST be replaced with a new power cord Please contact Customer Service Power Cord with 3 Prong Grounding Plug and Current Detection Device The power cord is equipped with a 3 Prong Grounding Plug which ...

Страница 5: ...tion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or volatile objects spread in the air 2 Near high frequency devices such as welding machines medical equipment etc INSTALLATION INSTRUCTIONS Requirements for Electric Connection Follow the Electric Safet...

Страница 6: ...ce Width 5 1 cm 2 Length Long enough to fit inside the window frame Thickness To determine the thickness place a piece of wood on the window sill to make it 1 3 cm 1 2 higher than the top of the storm window frame or vinyl frame Attach securely with nails or screws not included Storm window Frame 5 1 cm 2 piece of wood 1 3 cm 1 2 INSTALLATION INSTRUCTIONS Where to Install the Unit Ensure there is ...

Страница 7: ... Guide Rail Window Unit Top Mounting Rail Seal Strip PARTS LIST Parts and Tools Needed Power Plug Air Outlet Frame Upper Guide Rail Location Control Panel Power Cord Air Inlet Panel Fan Direction Adjusting Rod Upper guide rail may be attached on some units Foam Top Gasket Without Adhesive Window Sash Seal With Adhesive Flathead screwdriver ...

Страница 8: ...rame with one hand while extending Flexible Screen with other hand Slide edge of Flexible Screen into track on side of unit Slide the upper and lower ends of the Flexible Screen Frame into the Upper and Lower Guide Rails Upper Guide Rail Upper Guide Rail Left Right Top Mounting Rail Seal Strip Flexible Screen Upper Guide Rail Frame Frame 3 4 1 2 INSTALLATION INSTRUCTIONS Lower Guide Rail NOTICE Th...

Страница 9: ...he rear must be maintained 5 6 8 INSTALLATION INSTRUCTIONS NOTICE This picture is for reference only Please refer to the actual product for the appearance BACK FRONT Upper Guide Rail Lower Guide Rail Window Frame Horizontal or inclined about 3 To install the Window Sash Seal cut the seal to fit the length of the window Peel off the backing and attach to window sash and window sill Note To install ...

Страница 10: ... into the room If the strip does not properly fit to your window obtain appropriate material at a local store to provide a proper seal 9 Foam Top Gasket Without Adhesive INSTALLATION INSTRUCTIONS NOTICE This picture is for reference only Please refer to the actual product for the appearance ...

Страница 11: ...s and evaporates unwanted moisture without extra cooling Sleep Mode Automatically increases the set temperature 2 after the first hour and another 2 after the second hour This feature limits compressor usage and conserves energy Energy Saver Mode Automatically shuts off both compressor and fan when desired temperature is reached to conserve energy Loss of Power Protection with Auto Restart Remembe...

Страница 12: ... increments by 0 5 hours OPERATING INSTRUCTIONS Function Control Display DESCRIPTION FUNCTION Auto Fan Mode In this mode fan speed will automatically adjust to provide optimum comfort with the set temperature Cannot be used when in FAN only mode Cool Mode Air conditioner operates under COOL mode Cooling indicator will be on Press Fan Speed button to adjust the fan speed Energy Saver Mode Air condi...

Страница 13: ...le in COOL DRY and ENERGY SAVER mode to maintain the most comfortable temperature Timer Button Press this button to initiate AUTO ON AUTO OFF timer Press this button twice to cancel auto timer i Feel Button i Feel function will activate after pressing this button This will work with the rooms ambient temperature sending the remote programmed thermostat temperature to the unit every 10 minutes If p...

Страница 14: ... to the user s preference Adjust the air frame up or down to direct the air flow according to the user s preference OPERATING INSTRUCTIONS Air Flow Adjustment NOTICE This picture is for reference only Please refer to the actual product for the appearance Air outlet frame ...

Страница 15: ...lot of dust in the operation environment then clean more frequently Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check the coils on the outdoor side of unit periodically to ensure they are not clogged with dirt or debris WARNING Turn off the air conditioner and disconnect the power cord from outlet before cleaning the...

Страница 16: ... Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the BATTERY COVER of battery box CLEANING AND MAINTENANCE ...

Страница 17: ...rigerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors occur please turn off the air conditioner and disconnect the power cord from the outlet immediately Please contact Customer Service at once Power cord is overheating or damaged Abnormal sound during ...

Страница 18: ... Codes appear please call Customer Service IF THESE SOLUTIONS FAIL PLEASE CALL 1 866 658 0466 FOR GREE CUSTOMER SERVICE BEFORE YOU CALL MALFUNCTION CODE SOLUTION F1 Please contact Customer Service F2 F4 FJ EP F0 H3 E2 E8 JF Malfunction Code ...

Страница 19: ...stat to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter s and clean Temperature is set too high Turn temperature setting down Air louvers are not adjusted properly Check and adjust louvers to direct air flow Air ventilation is blocked hindered Remove any object blocking air flow drapes blinds furniture etc Other doors and or wind...

Страница 20: ...e Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replacement parts or new units Exclusion of Implied Warranties GREE is not responsible for any consequential or incident...

Страница 21: ...21 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 68DCWAC ...

Отзывы: