Gree G16-5MCVWAC Скачать руководство пользователя страница 9

9

To install the 

Window Sash Seal

, cut the seal to 

fit the length of the window. Peel off the backing, 
and attach to window sash and window sill. 

Place the air conditioner on the sill with the 

Lower 

Guide Rail

 against the back edge. Center the unit, 

and close the window securely behind the 

Upper 

Guide Rail

. The unit should be slightly tilted to the 

outside. Use a level: about 1/3 bubble will show 
correct slant.

To install the fixed bracket, attach the bracket to the 
window side sash with 

1 Type B Screw

. This prevents 

broken glass or damage to the windows. 

Front View

Side View

Vinyl 

Window

Wooden 

Window

 

NOTE:  

Top Rail and sliding panels at each side are offset to provide the proper pitch to the 

rear of .8 cm (5/16”). This is necessary for proper condensed water utilization and drainage. If 

you are not using the side panels for any reason, this pitch to the rear must be maintained.

5

6

8

 Note: 

To install the air conditioner onto 

the window sill, it is recommended to use 2 
PEOPLE.

INSTALLATION INSTRUCTIONS

NOTICE:

 

This picture is for reference only.  Please refer to the actual product for the appearance.

BACK

FRONT

Upper Guide 
Rail

Lower Guide 
Rail

Window Frame

Horizontal or inclined about 3°

Extend the left and right 

Flexible Screens

 to the 

window sashes. Install 

2 Type B Screws 

in holes in the 

upper 

Flexible Screen

 Frame and 

1 Type B Screw

 

into middle of Upper Guide Rail. Attach bottom of the 

Flexible Screen

 Frame to the window sill, with 

2 Type 

B Screws

.

 Note: 

In order to prevent the window 

sill from splitting drive the pilot holes before 
inserting the screws.

Window 
Sill

Window 
Frame

Type B Screws (2)

Type B Screws (3)

7

Содержание G16-5MCVWAC

Страница 1: ...rial numbers below for your records Model Serial Date Purchased Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please vi...

Страница 2: ...STALLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 CLEANING MAINTENANCE 12 BEFORE YOU CALL 13 14 WARRANTY 15 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please refe...

Страница 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Страница 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Страница 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Страница 6: ...easily out the back of the unit and won t affect others The window should be able to withstand the weight of the unit Select a window where noise and outflow air emitted by unit will not affect others...

Страница 7: ...RUCTIONS Parts and Tools Needed Upper guide rail may be attached on some units Type A Screws 4 Fixed Bracket for Window 1 Type B Screws 6 Flexible Screen 2 Upper Guide Rail Window Unit Foam Top Gasket...

Страница 8: ...uide Rail Top Mounting Rail Seal Strip 1 2 INSTALLATION INSTRUCTIONS NOTICE This picture is for reference only Please refer to the actual product for the appearance Remove backing from seal strip Note...

Страница 9: ...6 This is necessary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained 5 6 8 Note To install the air cond...

Страница 10: ...actual product for the appearance Insert the Foam Top Gasket between the glass and the window to prevent air from getting into the room If the strip does not properly fit to your window obtain appropr...

Страница 11: ...mp Dial Mode Dial Cool Mode Rotate Mode Dial to Low Cool or High Cool To set desired room temperature rotate Temp Dial to the desired setting Range of cooling is 1 to 7 with 7 being coolest temperatur...

Страница 12: ...ly Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check the coils on the outdoor side of unit periodically to ensure they...

Страница 13: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Страница 14: ...cooling ice forming on back of unit Set the unit at High FAN mode or High COOL mode and adjust the ther mostat to a higher temperature Room is not cooling no ice on back of unit Air restricted due to...

Страница 15: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Страница 16: ...16 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 5MWAC...

Отзывы: