•  Use caution when unpacking and installing. Fins 

may be sharp and could harm you.

•  Do not stop the unit by pulling out the power plug. 

This may cause electric shock or fire.

•   Replace immediately any part that has become 

frayed or damaged. Do not use a cord that 

shows damage or cracks along the length or at 

the connector. A damaged power cord should 

be replaced with a new cord obtained from the 

manufacturer. Please contact Customer Service for 

replacement options.

•  Do not modify power cord length or share an outlet 

with another appliance. This may cause electric 

shock or fire.

•  Always use a dedicated power circuit. The voltage 

on the outlet should match the voltage rating on the 

rating plate.

•  The power cord is equipped with a 3-prong 

grounding plug which can only be used with a 

standard 3-prong wall outlet to minimize the 

possibility of electric shock hazard. Where 

a 2-prong outlet is encountered, it is your 

responsibility to have it replaced with a properly 

grounded 3-prong wall outlet.

•  Do not use the outlet if it is loose or damaged. 

It may cause electric shock.

•   Do not open the unit during operation. It may cause 

electric shock.  

•   Keep away from heating appliances, flammable 

gas, or combustibles such as gasoline, benzene, 

thinner, etc.  

•  Ventilate room before operating air conditioner if 

there is a gas leak from another appliance.

•  Never use an extension cord, surge protector, or 

multi-outlet adapter with this unit.

•  Plug in power cord properly. Always unplug your air 

conditioner by pulling on the power plug. Grip plug 

firmly and unplug to remove.  

•  Do not disassemble or modify the unit.  
•  Do not operate with wet hands. 
•  Do not clean with water that may run inside the 

units electrical parts. This may cause failure of the 

machine or electric shock.  

•   Do not place obstacles around air-inlets or inside of 

air-outlet.  

•  Switch off the unit and unplug the unit before 

cleaning.  

•  To prevent injury, when the air filter needs to be 

removed, do not touch the metal parts of the unit.  

•  Only clean outside of the unit, use only a mild 

detergent. 

•  The filter(s) should be checked once a month, or 

every 250 hours, to see if cleaning is necessary. 

Always insert the filters securely. 

•  Do not place heavy objects on the power cord. 

Ensure that the power cord is not compressed. 

•  Turn off the main power switch when not using the 

unit for a long period of time. 

•  All air conditioners contain refrigerants which, 

under federal law, must be removed prior to 

disposal.  If you are getting rid of an old product 

with refrigerants, check with the company handling 

disposal about what to do.

•  These R410A air conditioning systems require 

contractors and technicians to use tools, equipment 

and safety standards approved for use with this 

refrigerant.

WARNING

Please read and understand this entire manual before attempting to assemble, operate or install your 
window air conditioner unit. Use this air conditioner only as instructed in this manual. While this manual 
covers a wide variety of troubleshooting, the instructions are not meant to cover every situation that may 
occur. Caution and common sense are to be practiced when installing, operating or maintaining your air 
conditioner.

We recommend 2 people to unpack and install.

SYMBOL INDICATES A HAZARDOUS SITUATION WHICH IF NOT AVOIDED 
COULD RESULT IN SERIOUS INJURY OR DEATH.

SAFETY INFORMATION

Содержание G16-5MCVWAC

Страница 1: ...rial numbers below for your records Model Serial Date Purchased Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please vi...

Страница 2: ...STALLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 CLEANING MAINTENANCE 12 BEFORE YOU CALL 13 14 WARRANTY 15 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please refe...

Страница 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Страница 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Страница 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Страница 6: ...easily out the back of the unit and won t affect others The window should be able to withstand the weight of the unit Select a window where noise and outflow air emitted by unit will not affect others...

Страница 7: ...RUCTIONS Parts and Tools Needed Upper guide rail may be attached on some units Type A Screws 4 Fixed Bracket for Window 1 Type B Screws 6 Flexible Screen 2 Upper Guide Rail Window Unit Foam Top Gasket...

Страница 8: ...uide Rail Top Mounting Rail Seal Strip 1 2 INSTALLATION INSTRUCTIONS NOTICE This picture is for reference only Please refer to the actual product for the appearance Remove backing from seal strip Note...

Страница 9: ...6 This is necessary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained 5 6 8 Note To install the air cond...

Страница 10: ...actual product for the appearance Insert the Foam Top Gasket between the glass and the window to prevent air from getting into the room If the strip does not properly fit to your window obtain appropr...

Страница 11: ...mp Dial Mode Dial Cool Mode Rotate Mode Dial to Low Cool or High Cool To set desired room temperature rotate Temp Dial to the desired setting Range of cooling is 1 to 7 with 7 being coolest temperatur...

Страница 12: ...ly Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check the coils on the outdoor side of unit periodically to ensure they...

Страница 13: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Страница 14: ...cooling ice forming on back of unit Set the unit at High FAN mode or High COOL mode and adjust the ther mostat to a higher temperature Room is not cooling no ice on back of unit Air restricted due to...

Страница 15: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Страница 16: ...16 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 5MWAC...