Safety Precautions 

 

This is the safety alert symbol. It is used to alert you to potential personal injury 

hazards. Obey all safety messages that follow this symbol to avoid possible injury or 
death. 

WARNING

 

This mark indicates procedures which, if improperly performed, might lead to the 

death or serious injury of the user.

 

CAUTION

 

This mark indicates procedures which, if improperly performed, might possibly result 

in personal harm to the user, or damage to property.

 

NOTICE 

NOTICE is used to address practices not related to personal injury.

 

 

WARNING

 

1)

 

Instructions for installation and use of this product are provided by the manufacturer.   

2)

 

Installation must be performed in accordance with the requirements of NEC and CEC by appointed 
personnel only. 

3)

 

The installation should be left to the appointed service center and according to the instructions given in the 
manual. Improper installation may cause fall down, water leakage, electric shock or fire etc. 

4)

 

For operating the air conditioner pleasantly, please install it as outlined in this installation manual. 

5)

 

The power supply must adopt the special circuit with air switch protection and assure it has enough capacity

6)

 

Connect the indoor unit, BU module and outdoor unit with the room air conditioner piping and cord 
available from our standard parts. This installation manual describes the correct connections using the 
installation set available from our standard parts. 

7)

 

Before installation, check the parameter of power cord and make sure that it complies with the power 
supply requirement on the nameplate. Make sure the power supply is safe. 

8)

 

This air conditioner must be properly grounded through the receptacle to avoid electric shock. The ground 
wire shouldn’t be connected with gas pipe, water pipe, lightning arrester or telephone line. 

9)

 

If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant comes in contact 
with a flame, it produces toxic gas. 

10)

 

Do not power on until all installation work is complete. 

11)

 

During installation, make sure that the refrigerant pipe is attached firmly before you start up the compressor. 
Do not operate the compressor under the condition of refrigerant piping not attached properly with valve 
open. This may cause abnormal pressure in the refrigeration cycle that leads to breakage and even injury. 

12)

 

When installing and relocating the air conditioner, do not mix gases except the specified refrigerant 
(R410A) to enter the refrigerant cycle. If air or other gas enters the refrigerant cycle, the pressure inside the 
cycle will rise to an abnormally high value and cause breakage, injury, etc. 

13)

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety. Children should be 
supervised to ensure that they do not play with the appliance. 

14)

 

Never cut off or damage power cables and transmission wires. If the power cable or transmission line were 
damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to 
avoid a hazard. 

15)

 

After the power cord is connected, please install the cover of electric box to avoid danger. 

Содержание FXA2A-D

Страница 1: ...sing Gree air conditioners please read this owner s manual carefully before operation and keep it for future reference GREE reserves the right to interpret this manual which will be subject to any cha...

Страница 2: ...ors is conflict with the modes of outdoor units it will be indicated on the display of the wired controller in five seconds and then the indoor unit will stop In this case please harmonize their work...

Страница 3: ...f FXB5A D 10 4 Installation Instruction 11 5 Installation of Refrigerant Pipes 12 5 1 Allowable Length and Drop Height of Connecting Pipe 12 5 2 Installation of Piping Adapter FXA2A D FXA3A D and FXB5...

Страница 4: ......

Страница 5: ...he nameplate Make sure the power supply is safe 8 This air conditioner must be properly grounded through the receptacle to avoid electric shock The ground wire shouldn t be connected with gas pipe wat...

Страница 6: ...he power supply Otherwise it may cause electric shock or damage 28 Do not spray water on the air conditioner or it will cause malfunction or electric shock 29 The air conditioner is not support to ins...

Страница 7: ...well Otherwise it is very compact and has a flexible choice about the installation location such as the ceiling of parlor corridor balcony storeroom and etc 2 1 Names of Main Parts a FXA2A D b FXA3A...

Страница 8: ...es the running command and all indoor units stop once the outdoor unit is turned off Fig 2 2 4 Working Temperature Range Table 2 B D e r u t a r e p m e t e d i s t u O s t r o S 0 5 m u m i x a M 122...

Страница 9: ...en s reach please keep the unit away from children 3 The BU module is for indoor use If installing in the outdoors the location must be away from wind and rain Otherwise it maybe causes water leakage...

Страница 10: ...ine dimension Fig 3 mm Table 3 Sorts Indoor unit side mm inch Outdoor unit side mm inch Port A Port B Liquid pipe 6 35 1 4 6 35 1 4 9 52 3 8 Gas pipe 9 52 3 8 9 52 3 8 15 9 5 8 2 Installation and serv...

Страница 11: ...Fig 5 mm Table 4 Sorts Indoor unit side mm inch Outdoor unit side mm inch Port A Port B Port C Liquid pipe 6 35 1 4 6 35 1 4 6 35 1 4 9 52 3 8 Gas liquid 9 52 3 8 9 52 3 8 9 52 3 8 15 9 5 8 2 Install...

Страница 12: ...tline dimension Fig 7 mm Table 5 Sorts Indoor unit side mm inch Outdoor unit side mm inch Port A Port B Liquid pipe 6 5 1 4 6 5 1 4 9 7 3 8 Gas pipe 16 3 5 8 16 3 5 8 16 3 5 8 2 Installation and servi...

Страница 13: ...n Fig 9 mm Table 6 Sorts Indoor unit side mm inch Outdoor unit side mm inch Port A Port B Port C Liquid pipe 6 5 1 4 6 5 1 4 6 5 1 4 9 7 3 8 Gas liquid 16 3 5 8 16 3 5 8 16 3 5 8 16 3 5 8 2 Installati...

Страница 14: ...f FXB5A D 1 Outline dimension Fig 11 mm Table 7 Sorts Indoor unit side mm inch Outdoor unit side mm inch Liquid pipe 6 35 1 4 9 52 3 8 Gas pipe 9 52 3 8 15 9 5 8 2 Installation and service space NO Na...

Страница 15: ...he condensed water can be discharged 2 Reference to the size of hanger metal and drill 4 holes in the installation location 3 Hang the hanger bolts Fig 13 4 Fix the modules securely with the hanger bo...

Страница 16: ...2 L5 2A L2 L3 3B 40 131 Maximum allowable length Between outdoor and indoor units H1 30 99 Between outdoor units and BU modules H2 30 99 Between BU and BU modules H3 15 49 Between indoor and indoor un...

Страница 17: ...en the nuts with hands Then tighten the flaring nuts with torque wrench until you hear a click Fig 17 3 Sealing the unconnected port If the port of BU module indoor side does not connected to one indo...

Страница 18: ...BU module wrap the pipes to be brazed with sufficient wet cloths After brazing use wet cloths to cool off the pipes to be brazed sufficient Fig 19 3 Sealing the unconnected port If the port of BU modu...

Страница 19: ...with the process requirements Rosin joint or pin hole is not allowed 3 During the installation do not damage the pipeline The pipeline s radius of bending must be over than 200mm 8inch The pipes cann...

Страница 20: ...uts with torque wrench until you hear a click The spanner and torque wrench should be perpendicular to the refrigerant pipeline The following table for the torque required to tighten the nuts Table 10...

Страница 21: ...Pieces Sectional area 3 0 75 mm2 Transmission line Pieces Sectional area 2 1 5 mm2 Recommended cable of indoor unit Pieces Sectional area 4 0 75mm2 Capacity of the air switch GWHD 48S ND3CO 40A GWHD...

Страница 22: ...cause the hazard of electric shock 4 The reliable ground terminal should be provided and the ground wire cannot be connected to any of the following places a Water pipe b Coal gas pipe c Sewage pipe...

Страница 23: ...k of the air conditioner 3 Press the ends of the cable tightly onto the round terminals corresponding to the size of the screws 4 Pass the screw through the round terminals and fix it onto the termina...

Страница 24: ...ber ring In order to protect the power cable and transmission line from damaging by the hole the rubber ring cannot fall from that otherwise it may cause electrical shock or fire etc 4 Connect the pow...

Страница 25: ...ting indoor units make sure to connect refrigerant pipes and power cables to the same connection ports marked with matching signs A B C D and E 5 If the connecting wire is connected to the terminal in...

Страница 26: ...ht be water bends 2 The drainage pipeline is form of the hard PVC pipes for common purposes which can be purchased locally The diameter of the PVC pipes is not less than 31mm 1 1 4inch and the pipelin...

Страница 27: ...onnected Flash 4 times Indoor unit E is connected Flash 5 times Indoor unit A gas tube temperature sensor error Flash 1 time b7 b7 indoor unit address Indoor unit A liquid tube temperature sensor erro...

Страница 28: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com 66174100032...

Отзывы: