Ducted Type Split Air-Conditioner Units(Inverter Series)
9
3.1 Dimension of Outdoor Unit and Mounting Hole
Unit Outline and Installation Dimension
Fig.16
Unit: mm
Model
A
B
C
D
E
FGR25Pd/DNa-M(O)
940
460
1615
610
486
FGR30Pd/DNa-M(O)
940
460
1615
610
486
3.2 Installation Space Requirement
If all sides of the ODU (including the top) are surrounded by walls, process according to the
following requirements for installation space:
Unit: mm
Fig.17
3.3 Refrigerant Pipe Connection
NOTES:
Do not loosen the cap of the pipes when connecting the pipes between the indoor unit and the
outdoor unit. Connecting the pipes as soon as possible after loosening the cap of the pipes to
avoid the entering of water and dusk. A metal pipe should be utilized if a pipe should be installed
through a wall.
The connection of the pipes should confirm to the following principles:
Make sure to lessen the length of connecting pipe, the height difference between the indoor
and outdoor unit, and the number of bends, and enlarge the diameter of bends.