background image

4

Figure 3

3. Remove shipping pads inside air conditioner next to

compressor. (See Figure B.)

Remove

shipping

pads

Figure B

4. Carefully slide the chassis into the sleeve.  Ensure that

the ground wire is not pinched or in the path of the

condenser fan.

5. Loosen locking plate screw and rotate tab with tab

behind wall case flange (See Figure C)  then tighten

locking plate screw.

Locking

Plate

Figure C

6. If outlet is on the left side of the unit, route power cord as

shown in Figure D.

Clamp

Power

Cord

Figure D

To replace front grille:

Tab 

Grille

Hook the tabs on the front grille even with the tabs on the case and

snap into place. Replace the screws and filter. Refer to Page 3,

Figure A.

VENT CONTROL AND AIR DIRECTION (See Figure E)

The vent control is located behind the front grille on the right

side of the air discharge area. When set at 

CLOSE

 only the air

inside the room will be circulated and conditioned. When set at

OPEN

, some inside air is exhausted outside.

Locating

Hole

Locating

Hole

Screw Hole

Screw Hole

OPEN position

(Mesh end toward back)

CLOSE position

(Mesh end toward front)

Figure E

Содержание 26TTW07HP230V1A

Страница 1: ...our product For proper operation please read and keep this manual carefully 26TTW09AC115V1A 26TTW09HP115V1A 26TTW12AC115V1A 26TTW09AC230V1A 26TTW09HC230V1A 26TTW07HP230V1A 26TTW09HP230V1A 26TTW12AC230...

Страница 2: ...ing is available for the type power plug on the unit DO NOT REMOVE THE GROUNDING PRONG FROM THE POWER CORD Note the types of acceptable plugs on the following figure Refer to the data specification pl...

Страница 3: ...own in Figure 3 Refer to the Installation Instructions supplied with the wall sleeve for a complete description of the installation procedure NOTE Wall sleeve is not shipped with chassis and must be p...

Страница 4: ...power cord as shown in Figure D Clamp Power Cord Figure D To replace front grille Tab Grille Hook the tabs on the front grille even with the tabs on the case and snap into place Replace the screws and...

Страница 5: ...louvers side to side to direct the air left or right DISCHARGE AIR GRILLE Figure 5 IMPORTANTNOTES 1 The unit is equipped with a rubber grommet mounted compressor These grommets are factory set and re...

Страница 6: ...6 WIRING Before wiring the unit please review the following warnings and cautions...

Страница 7: ...and remote as shown below and all its functions Then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote LOWERS TEMPERATURE OR TIME RAI...

Страница 8: ...l If setting HEAT mode by the remote control pressing the ON OFF button can t turn on the air conditioner Note The unit can only receive the signal for cool fan heat and it has no action when receivin...

Страница 9: ...remote controller for a long time please take out the batteries If the display on remote controller is fuzzy or there s no display replace the batteries AUXILIARY CONTROLS DIP SWITCHES The auxiliary...

Страница 10: ...C and 86F 30 C for both cooling and heating modes If you want the display to read the actual room temperature Select the fan only mode Note The fan speed to automatically set to the speed needed to p...

Страница 11: ...seconds then Timer light on Set light off In Timer mode Set temperature and fan speed keeps previously set temperature and fan speed Temperature display set temperature no display if power turn off P...

Страница 12: ...hen this switch is disabled DOWN set temperature range will be 61 86 When this switch is enabled UP set temperature range in cooling will be 65 86 F and that in heating will be 61 78 The default setti...

Страница 13: ...ect in the basepan and clog the condenser coil It is advisable to remove the unit from the sleeve and thoroughly clean the basepan and condenser coil on a periodic basis If the unit is installed ocean...

Страница 14: ...m refrigeration charge Replacement part or unit can be new or a remanufactured as provided at GREE S sole option LIMITATION OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHAN...

Страница 15: ...idents corrosive environment or other conditions beyond the control of GREE 8 Reimbursement for replacement parts or repair services which are not supplied or designated by GREE and which are specific...

Страница 16: ...66129917060 Gree Electric Appliances Inc 2015 All rights reserved Cat No 26 TTW 1OM Version 1 0...