![GREAT PLAINS Yield-Pro Air-Pro YP2425A Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/great-plains/yield-pro-air-pro-yp2425a/yield-pro-air-pro-yp2425a_operators-manual_2259528109.webp)
YP2425A
Maintenance and Lubrication
Great Plains
| 401-626M | 2019-06-11
105
Air Box Residue Clean-Out
Planting in extremely dusty conditions, particularly dusty
and humid conditions, or otherwise sticky soils, can lead
to air residue build-up inside the airbox. This residue can
cause seed delivery blockages.
Refer to Figure 137 and Figure 138 (Figure 137
depicts a partially and a completely plugged agitation
port, and build-up in the RH plenum chamber)
Whenever opening the airbox clean-out door , inspect
the agitation ports . If any are partially or completely
blocked, follow the clean-out instructions on this page.
Seasonally, remove the inspection ports on each of the
airbox, and inspect plenum chambers 1 (LH) and
16 (RH). If any build-up is observed, follow the more
comprehensive inspection steps and clean-out
instructions on this page.
1. Spot the planter at a suitable location for clean-out
and follow the parking instructions (page 56).
2. If seed is loaded, close the slide gate for the hopper
or bulk seed box (page 99).
3. Set out a tarp for recovery of any expected seed still
in the airbox. Open the airbox clean-out door .
4. Remove the inspection port covers from each end of
the airbox (not shown in figures).
5. Use an indelible marker to identify the hoses on seed
hose ports 1 through 16. Disconnect the clamps
and hoses.
Further disassembly of the airbox is not
recommended, as joints are sealed with silicone
adhesive, and would need to be cleaned and
resealed.
6. Inspect the agitation ports . Break up any build-up.
Use a hooked tool or wire to pull smaller fragments
down through the ports. For larger fragments, reach
in through the inspection ports or vacuum them out
via those ports.
7. Inspect the entire plenum area for build-up. Break
up any deposits. Vacuum them out through the
inspection ports.
8. From the seed hose ports , inspect the seed air
ports . Break up any deposits. Vacuum out from
clean-out door.
9. With all ports and doors still open, operate the
planter fan to blow up any remaining loose residues.
10. Reconnect the seed hoses. Reinstall the inspection
port doors. Close the clean-out door.
Figure 137
Residue in Air Box Plenum
36443
36442
Flushing the airbox with water is not recommended.
If done, operate the fan for an extended period to
completely remove any moisture prior to storage or
field operations.
Figure 138
Airbox Section View LH
36441
1
2
5
4
3
Содержание Yield-Pro Air-Pro YP2425A
Страница 172: ...Table of Contents Index Table of Contents Index...
Страница 178: ...Great Plains 401 626M 2019 06 11 Table of Contents Index 174 YP2425A Table of Contents Index...
Страница 179: ...Table of Contents Index Table of Contents Index...
Страница 180: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index...