98Great Plains
| | 4/22/19
Great Plains
|
98
196-366m
Veris Drive Operating Instructions
Calibration Troubleshooting
If the time to run for calibration is less than 4
seconds, the cab console will display TIME TOO
LOW. Pressing the FUNCTION key will bring up the
ENTER TARGET AMOUNT screen. The target
should be raised to increase the calibration time. If
the time is greater than 255 seconds, the cab
console will display TIME TOO HIGH. Pressing the
FUNCTION key will bring up the ENTER TARGET
AMOUNT screen. The target should be lowered to
decrease the calibration time.
While rate calibration is running, one of four error
messages may be displayed:
Press Function key will exit rate calibration from
these error screens.
Message Cause
Solution
COMM TIMEOUT
Power to or communication with
the external controller was
interrupted during calibration.
Check power and
communication connections
from the cab console to the
external controller and rerun
calibration.
TIME OVER LIMIT
The external controller ran too
long in calibration.
Rerun calibration. If the same
message appears, call technical
support.
USER TERMINATED
The engage key was pressed
during calibration.
Rerun calibration.
CALIBRATE ERROR
The drive did not turn when
calibration began.
Check encoder cable and
connection, solenoid cable and
connection, and hydraulic lever
position.
Содержание 3N-3010
Страница 111: ...196 366m Table of Contents Index Appendix Great Plains 4 22 19 Table of Contents Index 107 Appendix TP 71244...
Страница 115: ...196 366m Table of Contents Index Appendix Great Plains 4 22 19 Table of Contents Index 111...
Страница 117: ...Table of Contents Index Table of Contents Index...
Страница 118: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index...