- 32 -
8.2 Other Malfunctions and Solutions (No display on LED wire controller)
Malfunctions
Observing
Reasons
Solution
Heat pump is
not running
LED wire controller
no display.
No power supply
Check cable and circuit
breaker if it is connected
LED wire controller.
displays the actual time.
Heat pump under standby
status
Startup heat pump to run.
LED wire controller
displays the actual
water temperature.
1. Water temperature is
reaching to setting value,
HP under constant
temperature status.
2. Heat pump just starts to
run.
3. Under defrosting.
1. Verify water temperature
setting.
2. Startup heat pump after a
few minutes.
3. LED wire controller should
display "Defrosting".
Water
temperature is
cooling when
HP runs under
heating mode
LED wire controller
displays actual water
temperature and no error
code displays.
1. Choose the wrong mode.
2. Figures show defects.
3. Controller defect.
1. Adjust the mode to proper
running
2. Replace the defect LED
wire controller, and then
check the status after
changing the running mode,
verifying the water inlet and
outlet temperature.
3. Replace or repair the heat
pump unit
Short running
LED displays actual water
temperature, no error code
displays.
1. Fan NO running.
2. Air ventilation is not
enough.
3. Refrigerant is not
enough.
1. Check the cable
connections between the
motor and fan, if necessary, it
should be replaced.
2. Check the location of heat
pump unit, and eliminate all
obstacles to make good air
ventilation.
3 Replace or repair the heat
pump unit.
water stains
Water stains on heat pump
unit.
1. Concreting.
2. Water leakage.
1. No action.
2. Check the titanium heat
exchanger carefully if it is any
defect.
Too much ice
on evaporator
Too much ice on
evaporator.
1. Check the location of heat
pump unit, and eliminate all
obstacles to make good air
ventilation.
2. Replace or repair the heat
pump unit.
Содержание 777590
Страница 2: ......
Страница 25: ...22 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIAGRAM 777590 777591 778375...
Страница 26: ...23 5 2 SWIMMING POOL HEAT PUMP WIRING DIAGRAM 778392...
Страница 32: ...29 7 3 How to know the current status...
Страница 36: ...33 9 Exploded Diagram Model 777590 777591...
Страница 56: ...53 7 3 C mo conocer el estado actual...
Страница 61: ...58 9 Diagrama Explosionado Modelo 777590 777591...
Страница 74: ...71 5 C blage Electrique 5 1 SCHEMA DE CABLAGE DE LA POMPE CHALEUR DE PISCINE 777590 777591 778375...
Страница 75: ...72 5 2 SCHEMA DE CABLAGE DE POMPE CHALEUR DE PISCINE 778392...
Страница 81: ...78 7 3 Comment savoir les tats actuels...
Страница 85: ...82 9 Sch ma eclat et entretien Mod le 777590 777591...
Страница 98: ...95 5 Elektrische Verkabelung 5 1 VERKABELUNGSDIAGRAMM DER SCHWIMMBECKEN W RMEPUMPE 777590 777591 778375...
Страница 99: ...96 5 2 VERKABELUNGSDIAGRAMM DER SCHWIMMBECKEN W RMEPUMPE 778392...
Страница 105: ...102 7 3 Den aktuellen Status abrufen...
Страница 109: ...106 9 Explosionszeichnung Modell 777590 777591...
Страница 123: ...120 5 2 PISCINA POMPA DI CALORE SCHEMA 778392 La parte delle linee punteggiate viene utilizzata solo in alcuni modelli...
Страница 129: ...126 7 3 C mo conocer el estado actual...
Страница 134: ...131 9 Disegno dei component Modello 777590 77591...
Страница 147: ...144 5 Fia o el trica 5 1 DIAGRAMA DE FIA O DA BOMBA DE CALOR DA PISCINA 777590 777591 778375...
Страница 148: ...145 5 2 DIAGRAMA DE FIA O DA BOMBA DE CALOR DA PISCINA 778392...
Страница 154: ...151 7 3 Como saber o status atual...
Страница 171: ...168 5 Elektrische bedrading 5 1 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA 777590 777591 778375...
Страница 172: ...169 5 2 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA 778392...
Страница 178: ...175 7 3 Hoe de huidige status te weten te komen...
Страница 182: ...179 9 Open geklapt diagram Modellen 777590 777591...
Страница 187: ......
Страница 188: ...A0158MGRE01...